Dataset
Methane Observations and Yearly Assessments (MOYA): Isotopic d13C methane measurements taken from Llanos de Moxos, Bolivia
Abstract
This dataset contains air sample measurements of isotopic d13C methane. The measurements were collected using regular flask samples at Llanos de Moxos, Bolivia. The samples were analysed by Royal Holloway University of London using continuous flow gas chromatography/isotope ratio mass spectrometry (CF-GC/IRMS).
Date of campaign:
-31 Mar 2017, location: -15.024 -64.811, Low to medium forest, with heights up to 7-8 meters, seasonally flooded
-26 May 2017, location: -14.572 -64.869, Open savanah, ocassionally flooded, with palms and scattered trees
-13 July 2017, location: -14.49 -64.86, Open savanah covered by grasses and herbs
-20 Aug 2017, location: -14.49 -64.86, Open savanah covered by grasses and herbs
These data were collected as part of the Methane Observations and Yearly Assessments (MOYA) project funded by the Natural Environment Research Council (NERC) (NE/N016211/1).
Details
Previous Info: |
No news update for this record
|
---|---|
Previously used record identifiers: |
No related previous identifiers.
|
Access rules: |
Access to these data is available to any registered CEDA user. Please Login or Register for a CEDA account to gain access.
Use of these data is covered by the following licence(s): http://www.nationalarchives.gov.uk/doc/open-government-licence/version/3/ When using these data you must cite them correctly using the citation given on the CEDA Data Catalogue record. |
Data lineage: |
Data were collected locally and sent to RHUL for analysis and deposited at the Centre for Environmental Data Analysis (CEDA) for archiving. |
Data Quality: |
Data are as given by the data provider, no quality control has been performed by the Centre for Environmental Data Analysis (CEDA)
|
File Format: |
Data are BADC-CSV formatted
|
Related Documents
Royal Holloway Greenhouse Gas Laboratory |
Process overview
Independent Instruments
RHUL-continuous-flow gas chromatography/isotope-ratio mass spectrometry (CF-GC/IRMS) system |
Output Description | None |
- units: ppm
- long_name: 1/CH4 (1/ppm)
- units: ppm
- long_name: CH4 (ppm) average
- units: ppm
- long_name: CH4 sd (ppm)
- long_name: Date
- units: DD/MM/YYYY
- long_name: Time
- units: hh:ss
- long_name: delta 13CH4 (permille)
- units: permille
- units: permille
- long_name: delta 13CH4 standard deviation (permille)
- units: 1
- long_name: no. of measurements
Co-ordinate Variables
Temporal Range
2017-03-31T00:00:00
2017-08-20T23:59:59
Geographic Extent
-14.4900° |
||
-64.8690° |
-64.8110° |
|
-15.0240° |