Dataset
Deriving Emissions related to Climate Change Network: CO2, CH4, N2O, and SF6 measurements from Ridge Hill Tall Tower, Herefordshire
Abstract
High frequency measurements of carbon dioxide (CO2), methane (CH4), nitrous oxide (N2O) and sulfur hexafluoride (SF6) have been taken at Ridge Hill tall tower as part of the UK DECC (Deriving Emissions linked to Climate Change) Network.
Ridge Hill (RGL) is a rural UK site located 13 km south-east of Hereford (population ~55,000), and 30 km south-west of Worcester (population ~94,000), in Herefordshire, UK. Measurements of SF6 and N2O have been taken using gas chromatography with an electron capture detector (GC-ECD), sampling from a height of 90 m above ground level. Measurements are also taken from inlet heights of 45 m and 90 m above ground level using laser-based techniques for CO2 and CH4. Due to the location of the site, far from strong sources of local pollution, measurements from this site are used to calculate emission maps of trace gas species in the UK in combination with other measurement stations in the UK (Bilsdale, Tacolneston and Heathfield) and Ireland (Mace Head).
This work was funded by Business Energy and Industrial Strategy (BEIS) contracts TRN1028/06/2015 and TRN1537/06/2018 to the University of Bristol.
Details
Previous Info: |
No news update for this record
|
---|---|
Previously used record identifiers: |
No related previous identifiers.
|
Access rules: |
Public data: access to these data is available to both registered and non-registered users.
Use of these data is covered by the following licence(s): http://www.nationalarchives.gov.uk/doc/open-government-licence/version/3/ When using these data you must cite them correctly using the citation given on the CEDA Data Catalogue record. |
Data lineage: |
Data were collected by the University of Bristol and deposited at the Centre for Environmental Data Analysis (CEDA) for archiving. |
Data Quality: |
Data are as given by the data provider, no quality control has been performed by the Centre for Environmental Data Analysis (CEDA).
|
File Format: |
NetCDF
|
Related Documents
Met Office website for Ridge Hill Tall Tower |
Process overview
Instrument/Platform pairings
Output Description | High-frequency measurements of all major greenhouse gases in NetCDF |
- standard_name: mole_fraction_of_carbon_dioxide_in_air
- units: 1e-6
- var_id: co2
- long_name: mole_fraction_of_carbon_dioxide_in_air
- names: mole_fraction_of_carbon_dioxide_in_air, mole fraction of carbon dioxide in air
- long_name: mole_fraction_of_carbon_dioxide_in_air_number_of_observations
- var_id: co2_number_of_observations
- names: mole_fraction_of_carbon_dioxide_in_air_number_of_observations
- units: 1e-6
- long_name: mole_fraction_of_carbon_dioxide_in_air_variability
- var_id: co2_variability
- names: mole_fraction_of_carbon_dioxide_in_air_variability
- units: 1e-9
- standard_name: mole_fraction_of_methane_in_air
- var_id: ch4
- long_name: mole_fraction_of_methane_in_air
- names: mole_fraction_of_methane_in_air, mole fraction of methane in air
- long_name: mole_fraction_of_methane_in_air_number_of_observations
- var_id: ch4_number_of_observations
- names: mole_fraction_of_methane_in_air_number_of_observations
- units: 1e-9
- long_name: mole_fraction_of_methane_in_air_variability
- var_id: ch4_variability
- names: mole_fraction_of_methane_in_air_variability
- units: 1e-9
- standard_name: mole_fraction_of_nitrous_oxide_in_air
- var_id: n2o
- long_name: mole_fraction_of_nitrous_oxide_in_air
- names: mole_fraction_of_nitrous_oxide_in_air, mole fraction of nitrous oxide in air
- var_id: n2o_integration_flag
- long_name: mole_fraction_of_nitrous_oxide_in_air_integration_flag
- names: mole_fraction_of_nitrous_oxide_in_air_integration_flag
- units: 1e-9
- long_name: mole_fraction_of_nitrous_oxide_in_air_repeatability
- var_id: n2o_repeatability
- names: mole_fraction_of_nitrous_oxide_in_air_repeatability
- var_id: n2o_status_flag
- long_name: mole_fraction_of_nitrous_oxide_in_air_status_flag
- names: mole_fraction_of_nitrous_oxide_in_air_status_flag
- units: 1e-12
- standard_name: mole_fraction_of_sulfur_hexafluoride_in_air
- long_name: mole_fraction_of_sulfur_hexafluoride_in_air
- var_id: sf6
- names: mole_fraction_of_sulfur_hexafluoride_in_air, mole fraction of sulfur hexafluoride in air
- long_name: mole_fraction_of_sulfur_hexafluoride_in_air_integration_flag
- var_id: sf6_integration_flag
- names: mole_fraction_of_sulfur_hexafluoride_in_air_integration_flag
- units: 1e-12
- long_name: mole_fraction_of_sulfur_hexafluoride_in_air_repeatability
- var_id: sf6_repeatability
- names: mole_fraction_of_sulfur_hexafluoride_in_air_repeatability
- long_name: mole_fraction_of_sulfur_hexafluoride_in_air_status_flag
- var_id: sf6_status_flag
- names: mole_fraction_of_sulfur_hexafluoride_in_air_status_flag
Co-ordinate Variables
- standard_name: time
- var_id: time
- names: time
Temporal Range
2012-01-01T00:00:00
Ongoing
Geographic Extent
51.9976° |
||
-2.5400° |
-2.5400° |
|
51.9976° |