This website uses cookies. By continuing to use this website you are agreeing to our use of cookies. 

Dataset

 

FAAM B558 SeptEx flight, number 16: Airborne atmospheric measurements from core instrument suite on board the BAE-146 aircraft

Update Frequency: As Needed
Latest Data Update: 2015-04-30
Status: Completed
Online Status: ONLINE
Publication State: Published
Publication Date: 2014-07-14
Download Stats: last 12 months
Dataset Size: 41 Files | 4GB

Abstract

Airborne atmospheric measurements from core instrument suite data on board the FAAM BAE-146 aircraft during flight 16 for NCAS general FAAM flying (SeptEx, Winter 2010) project.

Citable as:  Facility for Airborne Atmospheric Measurements; Natural Environment Research Council; Met Office (2014): FAAM B558 SeptEx flight, number 16: Airborne atmospheric measurements from core instrument suite on board the BAE-146 aircraft. NCAS British Atmospheric Data Centre, date of citation. https://catalogue.ceda.ac.uk/uuid/bb75f2cfe0ef4f39b95eccde865851ba
Abbreviation: Not defined
Keywords: SeptEx, FAAM, airborne, atmospheric measurments

Details

Previous Info:
No news update for this record
Previously used record identifiers:
No related previous identifiers.
Access rules:
Restricted data: please submit an application using the REQUEST ACCESS link for access.
Use of these data is covered by the following licence: http://licences.ceda.ac.uk/image/data_access_condition/faam_core.pdf. When using these data you must cite them correctly using the citation given on the CEDA Data Catalogue record.
Data lineage:

Data were collected by instrument scientists during the flight before preparation and delivery for archiving at the NCAS British Atmospheric Data Centre.

Data Quality:
Data collected by flight participants before preparation for archival with the British Atmospheric Data Centre
File Format:
Data are netCDF and NASA-Ames formatted. Ancillary files may be plain ASCII or PDF formatted. Image files may be PNG formatted.

Process overview

This dataset was generated by instruments deployed on platforms as listed below.

Mobile platform operations

Mobile Platform Operation 1 FAAM BAE-146 flight B558
Output Description

None

  • units: m-3
  • long_name: 2DC Concentration in size channel 0
  • var_id: 2DC_CH00
  • units: m-3
  • long_name: 2DC Concentration in size channel 1
  • var_id: 2DC_CH01
  • units: m-3
  • long_name: 2DC Concentration in size channel 10
  • var_id: 2DC_CH10
  • units: m-3
  • long_name: 2DC Concentration in size channel 11
  • var_id: 2DC_CH11
  • units: m-3
  • long_name: 2DC Concentration in size channel 12
  • var_id: 2DC_CH12
  • units: m-3
  • long_name: 2DC Concentration in size channel 13
  • var_id: 2DC_CH13
  • units: m-3
  • long_name: 2DC Concentration in size channel 14
  • var_id: 2DC_CH14
  • units: m-3
  • long_name: 2DC Concentration in size channel 15
  • var_id: 2DC_CH15
  • units: m-3
  • long_name: 2DC Concentration in size channel 16
  • var_id: 2DC_CH16
  • units: m-3
  • long_name: 2DC Concentration in size channel 17
  • var_id: 2DC_CH17
  • units: m-3
  • long_name: 2DC Concentration in size channel 18
  • var_id: 2DC_CH18
  • units: m-3
  • long_name: 2DC Concentration in size channel 19
  • var_id: 2DC_CH19
  • units: m-3
  • long_name: 2DC Concentration in size channel 2
  • var_id: 2DC_CH02
  • units: m-3
  • long_name: 2DC Concentration in size channel 20
  • var_id: 2DC_CH20
  • units: m-3
  • long_name: 2DC Concentration in size channel 21
  • var_id: 2DC_CH21
  • units: m-3
  • long_name: 2DC Concentration in size channel 22
  • var_id: 2DC_CH22
  • units: m-3
  • long_name: 2DC Concentration in size channel 23
  • var_id: 2DC_CH23
  • units: m-3
  • long_name: 2DC Concentration in size channel 24
  • var_id: 2DC_CH24
  • units: m-3
  • long_name: 2DC Concentration in size channel 25
  • var_id: 2DC_CH25
  • units: m-3
  • long_name: 2DC Concentration in size channel 26
  • var_id: 2DC_CH26
  • units: m-3
  • long_name: 2DC Concentration in size channel 27
  • var_id: 2DC_CH27
  • units: m-3
  • long_name: 2DC Concentration in size channel 28
  • var_id: 2DC_CH28
  • units: m-3
  • long_name: 2DC Concentration in size channel 29
  • var_id: 2DC_CH29
  • units: m-3
  • long_name: 2DC Concentration in size channel 3
  • var_id: 2DC_CH03
  • units: m-3
  • long_name: 2DC Concentration in size channel 30
  • var_id: 2DC_CH30
  • units: m-3
  • long_name: 2DC Concentration in size channel 31
  • var_id: 2DC_CH31
  • units: m-3
  • long_name: 2DC Concentration in size channel 4
  • var_id: 2DC_CH04
  • units: m-3
  • long_name: 2DC Concentration in size channel 5
  • var_id: 2DC_CH05
  • units: m-3
  • long_name: 2DC Concentration in size channel 6
  • var_id: 2DC_CH06
  • units: m-3
  • long_name: 2DC Concentration in size channel 7
  • var_id: 2DC_CH07
  • units: m-3
  • long_name: 2DC Concentration in size channel 8
  • var_id: 2DC_CH08
  • units: m-3
  • long_name: 2DC Concentration in size channel 9
  • var_id: 2DC_CH09
  • units: m s-2
  • long_name: Acceleration along the aircraft longitudinal axis (GIN) (positive forward)
  • var_id: ACLF_GIN
  • units: m s-2
  • long_name: Acceleration along the aircraft transverse axis (GIN) (positive starboard)
  • var_id: ACLS_GIN
  • units: m s-2
  • long_name: Acceleration along the aircraft vertical axis (GIN) (positive down)
  • var_id: ACLD_GIN
  • units: degree
  • long_name: Aircraft track angle POSAV GPS-aided Inertial Navigation unit
  • var_id: TRCK_GIN
  • units: m s-1
  • long_name: Aircraft velocity down from POS AV 510 GPS-aided Inertial Navigation unit
  • var_id: VELD_GIN
  • standard_name:
  • units: m s-1
  • long_name: Aircraft velocity east from POS AV 510 GPS-aided Inertial Navigation unit
  • var_id: VELE_GIN
  • units: m s-1
  • long_name: Aircraft velocity north from POS AV 510 GPS-aided Inertial Navigation unit
  • var_id: VELN_GIN
  • units: m
  • standard_name: altitude
  • long_name: Altitude from POS AV 510 GPS-aided Inertial Navigation unit
  • var_id: ALT_GIN
  • units: m
  • standard_name: altitude
  • long_name: Altitude from the XR5 GPS system.
  • var_id: GPS_ALT
  • units: degree
  • long_name: Angle of attack from the turbulence probe (positive, flow upwards wrt a/c axes)
  • var_id: AOA
  • units: degree
  • long_name: Angle of sideslip from the turbulence probe (positive, flow from left)
  • var_id: AOSS
  • long_name: CDP Channel Number
  • var_id: CDPCH
  • units:
  • units: hPa
  • long_name: Cabin pressure
  • var_id: CAB_PRES
  • units: degC
  • long_name: Cabin temperature at the core consoles
  • var_id: CAB_TEMP
  • units: micron
  • long_name: Calibrated channel diameter lower limits
  • var_id: PCAS2_D_L_CAL
  • units: micron
  • long_name: Calibrated channel diameter upper limits
  • var_id: PCAS2_D_U_CAL
  • units: hPa
  • long_name: Calibrated differential pressure between centre(P0) port and S10 static
  • var_id: P0_S10
  • units: hPa
  • long_name: Calibrated differential pressure between turbulence probe horizontal ports
  • var_id: PB_TURB
  • units: hPa
  • long_name: Calibrated differential pressure between turbulence probe vertical ports
  • var_id: PA_TURB
  • long_name: Composition of the aerosol used to calibrate channel diameter lower limits
  • var_id: PCAS2_D_L_COMP
  • units:
  • long_name: Composition of the aerosol used to calibrate channel diameter upper limits
  • var_id: PCAS2_D_U_COMP
  • units:
  • units: W m-2
  • standard_name: downwelling_shortwave_flux_in_air
  • long_name: Corrected downward short wave irradiance, clear dome
  • var_id: SW_DN_C
  • units: W m-2
  • long_name: Corrected downward short wave irradiance, red dome
  • var_id: RED_DN_C
  • units: W m-2
  • standard_name: upwelling_shortwave_flux_in_air
  • long_name: Corrected upward short wave irradiance, clear dome
  • var_id: SW_UP_C
  • units: W m-2
  • long_name: Corrected upward short wave irradiance, red dome
  • var_id: RED_UP_C
  • standard_name: dew_point_temperature
  • units: degK
  • long_name: Dew point from the General Eastern instrument.
  • var_id: TDEW_GE
  • units: m s-1
  • standard_name: eastward_wind
  • long_name: Eastward wind component from turbulence probe and GIN
  • var_id: U_C
  • units: m s-1
  • long_name: Eastwards velocity from the XR5 GPS system.
  • var_id: GPS_VELE
  • units: micron
  • long_name: Error in calibrated channel diameter lower limits
  • var_id: PCAS2_D_L_ERR
  • units: micron
  • long_name: Error in calibrated channel diameter upper limits
  • var_id: PCAS2_D_U_ERR
  • units: 1
  • long_name: Flag for 2DC Concentration in size channel 0
  • var_id: 2DC_CH00_FLAG
  • units: 1
  • long_name: Flag for 2DC Concentration in size channel 1
  • var_id: 2DC_CH01_FLAG
  • units: 1
  • long_name: Flag for 2DC Concentration in size channel 10
  • var_id: 2DC_CH10_FLAG
  • units: 1
  • long_name: Flag for 2DC Concentration in size channel 11
  • var_id: 2DC_CH11_FLAG
  • units: 1
  • long_name: Flag for 2DC Concentration in size channel 12
  • var_id: 2DC_CH12_FLAG
  • units: 1
  • long_name: Flag for 2DC Concentration in size channel 13
  • var_id: 2DC_CH13_FLAG
  • units: 1
  • long_name: Flag for 2DC Concentration in size channel 14
  • var_id: 2DC_CH14_FLAG
  • units: 1
  • long_name: Flag for 2DC Concentration in size channel 15
  • var_id: 2DC_CH15_FLAG
  • units: 1
  • long_name: Flag for 2DC Concentration in size channel 16
  • var_id: 2DC_CH16_FLAG
  • units: 1
  • long_name: Flag for 2DC Concentration in size channel 17
  • var_id: 2DC_CH17_FLAG
  • units: 1
  • long_name: Flag for 2DC Concentration in size channel 18
  • var_id: 2DC_CH18_FLAG
  • units: 1
  • long_name: Flag for 2DC Concentration in size channel 19
  • var_id: 2DC_CH19_FLAG
  • units: 1
  • long_name: Flag for 2DC Concentration in size channel 2
  • var_id: 2DC_CH02_FLAG
  • units: 1
  • long_name: Flag for 2DC Concentration in size channel 20
  • var_id: 2DC_CH20_FLAG
  • units: 1
  • long_name: Flag for 2DC Concentration in size channel 21
  • var_id: 2DC_CH21_FLAG
  • units: 1
  • long_name: Flag for 2DC Concentration in size channel 22
  • var_id: 2DC_CH22_FLAG
  • units: 1
  • long_name: Flag for 2DC Concentration in size channel 23
  • var_id: 2DC_CH23_FLAG
  • units: 1
  • long_name: Flag for 2DC Concentration in size channel 24
  • var_id: 2DC_CH24_FLAG
  • units: 1
  • long_name: Flag for 2DC Concentration in size channel 25
  • var_id: 2DC_CH25_FLAG
  • units: 1
  • long_name: Flag for 2DC Concentration in size channel 26
  • var_id: 2DC_CH26_FLAG
  • units: 1
  • long_name: Flag for 2DC Concentration in size channel 27
  • var_id: 2DC_CH27_FLAG
  • units: 1
  • long_name: Flag for 2DC Concentration in size channel 28
  • var_id: 2DC_CH28_FLAG
  • units: 1
  • long_name: Flag for 2DC Concentration in size channel 29
  • var_id: 2DC_CH29_FLAG
  • units: 1
  • long_name: Flag for 2DC Concentration in size channel 3
  • var_id: 2DC_CH03_FLAG
  • units: 1
  • long_name: Flag for 2DC Concentration in size channel 30
  • var_id: 2DC_CH30_FLAG
  • units: 1
  • long_name: Flag for 2DC Concentration in size channel 31
  • var_id: 2DC_CH31_FLAG
  • units: 1
  • long_name: Flag for 2DC Concentration in size channel 4
  • var_id: 2DC_CH04_FLAG
  • units: 1
  • long_name: Flag for 2DC Concentration in size channel 5
  • var_id: 2DC_CH05_FLAG
  • units: 1
  • long_name: Flag for 2DC Concentration in size channel 6
  • var_id: 2DC_CH06_FLAG
  • units: 1
  • long_name: Flag for 2DC Concentration in size channel 7
  • var_id: 2DC_CH07_FLAG
  • units: 1
  • long_name: Flag for 2DC Concentration in size channel 8
  • var_id: 2DC_CH08_FLAG
  • units: 1
  • long_name: Flag for 2DC Concentration in size channel 9
  • var_id: 2DC_CH09_FLAG
  • units: 1
  • long_name: Flag for Acceleration along the aircraft longitudinal axis (GIN) (positive forward)
  • var_id: ACLF_GIN_FLAG
  • units: 1
  • long_name: Flag for Acceleration along the aircraft transverse axis (GIN) (positive starboard)
  • var_id: ACLS_GIN_FLAG
  • units: 1
  • long_name: Flag for Acceleration along the aircraft vertical axis (GIN) (positive down)
  • var_id: ACLD_GIN_FLAG
  • units: 1
  • long_name: Flag for Aircraft track angle POSAV GPS-aided Inertial Navigation unit
  • var_id: TRCK_GIN_FLAG
  • units: 1
  • long_name: Flag for Aircraft velocity down from POS AV 510 GPS-aided Inertial Navigation unit
  • var_id: VELD_GIN_FLAG
  • units: 1
  • long_name: Flag for Aircraft velocity east from POS AV 510 GPS-aided Inertial Navigation unit
  • var_id: VELE_GIN_FLAG
  • units: 1
  • long_name: Flag for Aircraft velocity north from POS AV 510 GPS-aided Inertial Navigation unit
  • var_id: VELN_GIN_FLAG
  • units: 1
  • long_name: Flag for Altitude from POS AV 510 GPS-aided Inertial Navigation unit
  • var_id: ALT_GIN_FLAG
  • units: 1
  • long_name: Flag for Altitude from the XR5 GPS system.
  • var_id: GPS_ALT_FLAG
  • units: 1
  • long_name: Flag for Angle of attack from the turbulence probe (positive, flow upwards wrt a/c axes)
  • var_id: AOA_FLAG
  • units: 1
  • long_name: Flag for Angle of sideslip from the turbulence probe (positive, flow from left)
  • var_id: AOSS_FLAG
  • units: 1
  • long_name: Flag for Cabin pressure
  • var_id: CAB_PRES_FLAG
  • units: 1
  • long_name: Flag for Cabin temperature at the core consoles
  • var_id: CAB_TEMP_FLAG
  • units: 1
  • long_name: Flag for Calibrated differential pressure between centre(P0) port and S10 static
  • var_id: P0_S10_FLAG
  • units: 1
  • long_name: Flag for Calibrated differential pressure between turbulence probe horizontal ports
  • var_id: PB_TURB_FLAG
  • units: 1
  • long_name: Flag for Calibrated differential pressure between turbulence probe vertical ports
  • var_id: PA_TURB_FLAG
  • units: 1
  • long_name: Flag for Corrected downward short wave irradiance, clear dome
  • var_id: SW_DN_C_FLAG
  • units: 1
  • long_name: Flag for Corrected downward short wave irradiance, red dome
  • var_id: RED_DN_C_FLAG
  • units: 1
  • long_name: Flag for Corrected upward short wave irradiance, clear dome
  • var_id: SW_UP_C_FLAG
  • units: 1
  • long_name: Flag for Corrected upward short wave irradiance, red dome
  • var_id: RED_UP_C_FLAG
  • units: 1
  • long_name: Flag for Dew point from the General Eastern instrument.
  • var_id: TDEW_GE_FLAG
  • units: 1
  • long_name: Flag for Eastward wind component from turbulence probe and GIN
  • var_id: U_C_FLAG
  • units: 1
  • long_name: Flag for Eastwards velocity from the XR5 GPS system.
  • var_id: GPS_VELE_FLAG
  • units: 1
  • long_name: Flag for Groundspeed from POS AV 510 GPS-aided Inertial Navigation unit
  • var_id: GSPD_GIN_FLAG
  • units: 1
  • long_name: Flag for Heading from POSAV GPS-aided Inertial Navigation unit
  • var_id: HDG_GIN_FLAG
  • units: 1
  • long_name: Flag for Ice water content from 2DC
  • var_id: 2DC_IWC_FLAG
  • units: 1
  • long_name: Flag for Indicated air speed from the aircraft RVSM (air data) system.
  • var_id: IAS_RVSM_FLAG
  • units: 1
  • long_name: Flag for Internal sample humidity of the nephelometer
  • var_id: NEPH_HUM_FLAG
  • units: 1
  • long_name: Flag for Internal sample pressure of the Nephelometer
  • var_id: NEPH_PR_FLAG
  • units: 1
  • long_name: Flag for Internal sample temperature of the Nephelometer
  • var_id: NEPH_T_FLAG
  • units: 1
  • long_name: Flag for Latitude from POS AV 510 GPS-aided Inertial Navigation unit
  • var_id: LAT_GIN_FLAG
  • units: 1
  • long_name: Flag for Latitude from the XR5 GPS system.
  • var_id: LAT_GPS_FLAG
  • units: 1
  • long_name: Flag for Liquid water content from 2DC
  • var_id: 2DC_LWC_FLAG
  • units: 1
  • long_name: Flag for Longitude from POS AV 510 GPS-aided Inertial Navigation unit
  • var_id: LON_GIN_FLAG
  • units: 1
  • long_name: Flag for Longitude from the XR5 GPS system.
  • var_id: LON_GPS_FLAG
  • units: 1
  • long_name: Flag for Mole Fraction of Sulphur Dioxide in air from the TECO 43 instrument
  • var_id: SO2_TECO_FLAG
  • units: 1
  • long_name: Flag for Mole fraction of Carbon Monoxide in air from the AERO AL5002 instrument
  • var_id: CO_AERO_FLAG
  • units: 1
  • long_name: Flag for Mole fraction of NOx in air from the TECO 42 instrument
  • var_id: NOX_TECO_FLAG
  • units: 1
  • long_name: Flag for Mole fraction of Nitrogen Dioxide (NO2) in air from the TECO 42 instrument
  • var_id: NO2_TECO_FLAG
  • units: 1
  • long_name: Flag for Mole fraction of Nitrogen Monoxide (NO) in air from the TECO 42 instrument
  • var_id: NO_TECO_FLAG
  • units: 1
  • long_name: Flag for Mole fraction of ozone in air from the TECO 49 instrument
  • var_id: O3_TECO_FLAG
  • units: 1
  • long_name: Flag for Northward wind component from turbulence probe and GIN
  • var_id: V_C_FLAG
  • units: 1
  • long_name: Flag for Northwards velocity from the XR5 GPS system.
  • var_id: GPS_VELN_FLAG
  • units: 1
  • long_name: Flag for Particle concentration from the 2DC
  • var_id: 2DC_CONC_FLAG
  • units: 1
  • long_name: Flag for Pitch angle from POSAV GPS-aided Inertial Nav. unit (positive for nose up)
  • var_id: PTCH_GIN_FLAG
  • units: 1
  • long_name: Flag for Pitot static pressure inverted from RVSM (air data) system indicated airspeed
  • var_id: Q_RVSM_FLAG
  • units: 1
  • long_name: Flag for Pitot-static pressure from centre-port measurements corrrected for AoA and AoSS
  • var_id: PSP_TURB_FLAG
  • units: 1
  • long_name: Flag for Pressure altitude from the aircraft RVSM (air data) system
  • var_id: PALT_RVS_FLAG
  • units: 1
  • long_name: Flag for Radar height from the aircraft radar altimeter.
  • var_id: HGT_RADR_FLAG
  • units: 1
  • long_name: Flag for Raw data from the TWC probe Lyman alpha detector
  • var_id: TWC_DET_FLAG
  • units: 1
  • long_name: Flag for Roll angle from POSAV GPS-aided Inertial Nav. unit (positive for left wing up)
  • var_id: ROLL_GIN_FLAG
  • units: 1
  • long_name: Flag for Sample temperature in Kelvin from the TWC evaporator probe
  • var_id: TWC_TSAM_FLAG
  • units: 1
  • long_name: Flag for Solar azimuth derived from aircraft position and time.
  • var_id: SOL_AZIM_FLAG
  • units: 1
  • long_name: Flag for Solar zenith derived from aircraft position and time.
  • var_id: SOL_ZEN_FLAG
  • units: 1
  • long_name: Flag for Static pressure from S9 fuselage ports
  • var_id: P9_STAT_FLAG
  • units: 1
  • long_name: Flag for Static pressure from the aircraft RVSM (air data) system
  • var_id: PS_RVSM_FLAG
  • units: 1
  • long_name: Flag for True air speed from the aircraft RVSM (air data) system and deiced temperature.
  • var_id: TAS_RVSM_FLAG
  • units: 1
  • long_name: Flag for True air temperature from the Rosemeount non-deiced temperature sensor.
  • var_id: TAT_ND_R_FLAG
  • units: 1
  • long_name: Flag for True air temperature from the Rosemount deiced temperature sensor.
  • var_id: TAT_DI_R_FLAG
  • units: 1
  • long_name: Flag for True airspeed (dry-air) from turbulence probe
  • var_id: TAS_FLAG
  • units: 1
  • long_name: Flag for Uncorrected blue back scattering coefficient from TSI 3563 nephelometer.
  • var_id: BSC_BLUU_FLAG
  • units: 1
  • long_name: Flag for Uncorrected blue total scattering coefficient from TSI 3563 nephelometer.
  • var_id: TSC_BLUU_FLAG
  • units: 1
  • long_name: Flag for Uncorrected brightness temperature from the Heimann radiometer
  • var_id: BTHEIM_U_FLAG
  • units: 1
  • long_name: Flag for Uncorrected green back scattering coefficient from TSI 3563 nephelometer.
  • var_id: BSC_GRNU_FLAG
  • units: 1
  • long_name: Flag for Uncorrected green total scattering coefficient from TSI 3563 nephelometer.
  • var_id: TSC_GRNU_FLAG
  • units: 1
  • long_name: Flag for Uncorrected liquid water content from the Johnson Williams instrument.
  • var_id: LWC_JW_U_FLAG
  • units: 1
  • long_name: Flag for Uncorrected liquid water content from the Nevzorov probe
  • var_id: NV_LWC_U_FLAG
  • units: 1
  • long_name: Flag for Uncorrected red back scattering coefficient from TSI 3563 nephelometer.
  • var_id: BSC_REDU_FLAG
  • units: 1
  • long_name: Flag for Uncorrected red total scattering coefficient from TSI 3563 nephelometer.
  • var_id: TSC_REDU_FLAG
  • units: 1
  • long_name: Flag for Uncorrected total condensed water content from the Nevzorov probe.
  • var_id: NV_TCW_U_FLAG
  • units: 1
  • long_name: Flag for Upwards velocitiy from the XR5 GPS system.
  • var_id: GPS_VELZ_FLAG
  • units: 1
  • long_name: Flag for Upwelling infrared brightness temperature from the Heimann radiometer.
  • var_id: BTHEIM_C_FLAG
  • units: 1
  • long_name: Flag for Vertical wind component from turbulence probe and GIN
  • var_id: W_C_FLAG
  • long_name: Flag for droplet concentration from CDP channels 2 to 30 included
  • var_id: CDP_FLAG
  • units:
  • long_name: Flag for droplet concentration from PCASP2 (SPP200) channels 2 to 30 included
  • var_id: PCAS2_FLAG
  • units:
  • units: 1
  • long_name: Flag for rate-of-change of GIN heading
  • var_id: HDGR_GIN_FLAG
  • units: 1
  • long_name: Flag for rate-of-change of GIN pitch angle
  • var_id: PITR_GIN_FLAG
  • units: 1
  • long_name: Flag for rate-of-change of GIN roll angle
  • var_id: ROLR_GIN_FLAG
  • units: degree
  • long_name: Heading from POSAV GPS-aided Inertial Navigation unit
  • standard_name: platform_yaw_angle
  • var_id: HDG_GIN
  • units: m s-1
  • long_name: Indicated air speed from the aircraft RVSM (air data) system.
  • var_id: IAS_RVSM
  • units: %
  • long_name: Internal sample humidity of the nephelometer
  • var_id: NEPH_HUM
  • units: hPa
  • long_name: Internal sample pressure of the Nephelometer
  • var_id: NEPH_PR
  • units: K
  • long_name: Internal sample temperature of the Nephelometer
  • var_id: NEPH_T
  • units: ppb
  • long_name: Mole fraction of Carbon Monoxide in air from the AERO AL5002 instrument
  • var_id: CO_AERO
  • units: ppb
  • long_name: Mole fraction of NOx in air from the TECO 42 instrument
  • var_id: NOX_TECO
  • units: ppb
  • standard_name: mole_fraction_of_ozone_in_air
  • long_name: Mole fraction of ozone in air from the TECO 49 instrument
  • var_id: O3_TECO
  • units: micron
  • long_name: Nominal uncalibrated channel diameter lower limits as given in the instrument manual
  • var_id: PCAS2_D_L_NOM
  • units: micron
  • long_name: Nominal uncalibrated channel diameter upper limits as given in the instrument manual
  • var_id: PCAS2_D_U_NOM
  • units: m s-1
  • standard_name: northward_wind
  • long_name: Northward wind component from turbulence probe and GIN
  • var_id: V_C
  • units: m s-1
  • long_name: Northwards velocity from the XR5 GPS system.
  • var_id: GPS_VELN
  • long_name: PCASP (SPP200) Channel Number
  • var_id: PCAS2CH
  • units:
  • units: cm-3
  • long_name: PCASP2 (SPP200) conc in size channel 1
  • var_id: PCAS2_01
  • units: cm-3
  • long_name: PCASP2 (SPP200) conc in size channel 10
  • var_id: PCAS2_10
  • units: cm-3
  • long_name: PCASP2 (SPP200) conc in size channel 11
  • var_id: PCAS2_11
  • units: cm-3
  • long_name: PCASP2 (SPP200) conc in size channel 12
  • var_id: PCAS2_12
  • units: cm-3
  • long_name: PCASP2 (SPP200) conc in size channel 13
  • var_id: PCAS2_13
  • units: cm-3
  • long_name: PCASP2 (SPP200) conc in size channel 14
  • var_id: PCAS2_14
  • units: cm-3
  • long_name: PCASP2 (SPP200) conc in size channel 15
  • var_id: PCAS2_15
  • units: cm-3
  • long_name: PCASP2 (SPP200) conc in size channel 16
  • var_id: PCAS2_16
  • units: cm-3
  • long_name: PCASP2 (SPP200) conc in size channel 17
  • var_id: PCAS2_17
  • units: cm-3
  • long_name: PCASP2 (SPP200) conc in size channel 18
  • var_id: PCAS2_18
  • units: cm-3
  • long_name: PCASP2 (SPP200) conc in size channel 19
  • var_id: PCAS2_19
  • units: cm-3
  • long_name: PCASP2 (SPP200) conc in size channel 2
  • var_id: PCAS2_02
  • units: cm-3
  • long_name: PCASP2 (SPP200) conc in size channel 20
  • var_id: PCAS2_20
  • units: cm-3
  • long_name: PCASP2 (SPP200) conc in size channel 21
  • var_id: PCAS2_21
  • units: cm-3
  • long_name: PCASP2 (SPP200) conc in size channel 22
  • var_id: PCAS2_22
  • units: cm-3
  • long_name: PCASP2 (SPP200) conc in size channel 23
  • var_id: PCAS2_23
  • units: cm-3
  • long_name: PCASP2 (SPP200) conc in size channel 24
  • var_id: PCAS2_24
  • units: cm-3
  • long_name: PCASP2 (SPP200) conc in size channel 25
  • var_id: PCAS2_25
  • units: cm-3
  • long_name: PCASP2 (SPP200) conc in size channel 26
  • var_id: PCAS2_26
  • units: cm-3
  • long_name: PCASP2 (SPP200) conc in size channel 27
  • var_id: PCAS2_27
  • units: cm-3
  • long_name: PCASP2 (SPP200) conc in size channel 28
  • var_id: PCAS2_28
  • units: cm-3
  • long_name: PCASP2 (SPP200) conc in size channel 29
  • var_id: PCAS2_29
  • units: cm-3
  • long_name: PCASP2 (SPP200) conc in size channel 3
  • var_id: PCAS2_03
  • units: cm-3
  • long_name: PCASP2 (SPP200) conc in size channel 30
  • var_id: PCAS2_30
  • units: cm-3
  • long_name: PCASP2 (SPP200) conc in size channel 4
  • var_id: PCAS2_04
  • units: cm-3
  • long_name: PCASP2 (SPP200) conc in size channel 5
  • var_id: PCAS2_05
  • units: cm-3
  • long_name: PCASP2 (SPP200) conc in size channel 6
  • var_id: PCAS2_06
  • units: cm-3
  • long_name: PCASP2 (SPP200) conc in size channel 7
  • var_id: PCAS2_07
  • units: cm-3
  • long_name: PCASP2 (SPP200) conc in size channel 8
  • var_id: PCAS2_08
  • units: cm-3
  • long_name: PCASP2 (SPP200) conc in size channel 9
  • var_id: PCAS2_09
  • units: m-3
  • long_name: Particle concentration from the 2DC
  • var_id: 2DC_CONC
  • units: percent
  • long_name: Percentage error in PCASP2 (SPP200) conc in size channel 1
  • var_id: PCAS2_01_err
  • units: percent
  • long_name: Percentage error in PCASP2 (SPP200) conc in size channel 10
  • var_id: PCAS2_10_err
  • units: percent
  • long_name: Percentage error in PCASP2 (SPP200) conc in size channel 11
  • var_id: PCAS2_11_err
  • units: percent
  • long_name: Percentage error in PCASP2 (SPP200) conc in size channel 12
  • var_id: PCAS2_12_err
  • units: percent
  • long_name: Percentage error in PCASP2 (SPP200) conc in size channel 13
  • var_id: PCAS2_13_err
  • units: percent
  • long_name: Percentage error in PCASP2 (SPP200) conc in size channel 14
  • var_id: PCAS2_14_err
  • units: percent
  • long_name: Percentage error in PCASP2 (SPP200) conc in size channel 15
  • var_id: PCAS2_15_err
  • units: percent
  • long_name: Percentage error in PCASP2 (SPP200) conc in size channel 16
  • var_id: PCAS2_16_err
  • units: percent
  • long_name: Percentage error in PCASP2 (SPP200) conc in size channel 17
  • var_id: PCAS2_17_err
  • units: percent
  • long_name: Percentage error in PCASP2 (SPP200) conc in size channel 18
  • var_id: PCAS2_18_err
  • units: percent
  • long_name: Percentage error in PCASP2 (SPP200) conc in size channel 19
  • var_id: PCAS2_19_err
  • units: percent
  • long_name: Percentage error in PCASP2 (SPP200) conc in size channel 2
  • var_id: PCAS2_02_err
  • units: percent
  • long_name: Percentage error in PCASP2 (SPP200) conc in size channel 20
  • var_id: PCAS2_20_err
  • units: percent
  • long_name: Percentage error in PCASP2 (SPP200) conc in size channel 21
  • var_id: PCAS2_21_err
  • units: percent
  • long_name: Percentage error in PCASP2 (SPP200) conc in size channel 22
  • var_id: PCAS2_22_err
  • units: percent
  • long_name: Percentage error in PCASP2 (SPP200) conc in size channel 23
  • var_id: PCAS2_23_err
  • units: percent
  • long_name: Percentage error in PCASP2 (SPP200) conc in size channel 24
  • var_id: PCAS2_24_err
  • units: percent
  • long_name: Percentage error in PCASP2 (SPP200) conc in size channel 25
  • var_id: PCAS2_25_err
  • units: percent
  • long_name: Percentage error in PCASP2 (SPP200) conc in size channel 26
  • var_id: PCAS2_26_err
  • units: percent
  • long_name: Percentage error in PCASP2 (SPP200) conc in size channel 27
  • var_id: PCAS2_27_err
  • units: percent
  • long_name: Percentage error in PCASP2 (SPP200) conc in size channel 28
  • var_id: PCAS2_28_err
  • units: percent
  • long_name: Percentage error in PCASP2 (SPP200) conc in size channel 29
  • var_id: PCAS2_29_err
  • units: percent
  • long_name: Percentage error in PCASP2 (SPP200) conc in size channel 3
  • var_id: PCAS2_03_err
  • units: percent
  • long_name: Percentage error in PCASP2 (SPP200) conc in size channel 30
  • var_id: PCAS2_30_err
  • units: percent
  • long_name: Percentage error in PCASP2 (SPP200) conc in size channel 4
  • var_id: PCAS2_04_err
  • units: percent
  • long_name: Percentage error in PCASP2 (SPP200) conc in size channel 5
  • var_id: PCAS2_05_err
  • units: percent
  • long_name: Percentage error in PCASP2 (SPP200) conc in size channel 6
  • var_id: PCAS2_06_err
  • units: percent
  • long_name: Percentage error in PCASP2 (SPP200) conc in size channel 7
  • var_id: PCAS2_07_err
  • units: percent
  • long_name: Percentage error in PCASP2 (SPP200) conc in size channel 8
  • var_id: PCAS2_08_err
  • units: percent
  • long_name: Percentage error in PCASP2 (SPP200) conc in size channel 9
  • var_id: PCAS2_09_err
  • units: hPa
  • long_name: Pitot static pressure inverted from RVSM (air data) system indicated airspeed
  • var_id: Q_RVSM
  • units: hPa
  • long_name: Pitot-static pressure from centre-port measurements corrrected for AoA and AoSS
  • var_id: PSP_TURB
  • units: m
  • standard_name: altitude
  • long_name: Pressure altitude from the aircraft RVSM (air data) system
  • var_id: PALT_RVS
  • units: m
  • standard_name: height
  • long_name: Radar height from the aircraft radar altimeter.
  • var_id: HGT_RADR
  • units: bits
  • long_name: Raw data from the TWC probe Lyman alpha detector
  • var_id: TWC_DET
  • long_name: Refractive index of the aerosol used to calibrate channel diameter lower limits
  • var_id: PCAS2_D_L_RI
  • units:
  • long_name: Refractive index of the aerosol used to calibrate channel diameter upper limits
  • var_id: PCAS2_D_U_RI
  • units:
  • units: K
  • long_name: Sample temperature in Kelvin from the TWC evaporator probe
  • var_id: TWC_TSAM
  • units: degree
  • long_name: Solar azimuth derived from aircraft position and time.
  • var_id: SOL_AZIM
  • units: degree
  • long_name: Solar zenith derived from aircraft position and time.
  • var_id: SOL_ZEN
  • units: hPa
  • long_name: Static pressure from S9 fuselage ports
  • var_id: P9_STAT
  • units: hPa
  • standard_name: air_pressure
  • long_name: Static pressure from the aircraft RVSM (air data) system
  • var_id: PS_RVSM
  • var_id: Time
  • long_name: Time UTC integer seconds past midnight
  • long_name: Time UTC seconds past midnight for 2D-C and 2D-P
  • var_id: 2DTSPM
  • long_name: Time UTC seconds past midnight for PCASP2 (SPP200)
  • standard_name: Time
  • var_id: PCAS2TSPM
  • standard_name: air_temperature
  • units: degK
  • long_name: True air temperature from the Rosemeount non-deiced temperature sensor.
  • var_id: TAT_ND_R
  • standard_name: air_temperature
  • units: degK
  • long_name: True air temperature from the Rosemount deiced temperature sensor.
  • var_id: TAT_DI_R
  • units: m s-1
  • long_name: True airspeed (dry-air) from turbulence probe
  • var_id: TAS
  • units: m-1
  • long_name: Uncorrected blue back scattering coefficient from TSI 3563 nephelometer.
  • var_id: BSC_BLUU
  • units: m-1
  • long_name: Uncorrected blue total scattering coefficient from TSI 3563 nephelometer.
  • var_id: TSC_BLUU
  • standard_name: brightness_temperature
  • units: degK
  • long_name: Uncorrected brightness temperature from the Heimann radiometer
  • var_id: BTHEIM_U
  • units: m-1
  • long_name: Uncorrected green back scattering coefficient from TSI 3563 nephelometer.
  • var_id: BSC_GRNU
  • units: m-1
  • long_name: Uncorrected green total scattering coefficient from TSI 3563 nephelometer.
  • var_id: TSC_GRNU
  • units: gram kg-1
  • long_name: Uncorrected liquid water content from the Johnson Williams instrument.
  • var_id: LWC_JW_U
  • units: gram m-3
  • long_name: Uncorrected liquid water content from the Nevzorov probe
  • var_id: NV_LWC_U
  • units: m-1
  • long_name: Uncorrected red back scattering coefficient from TSI 3563 nephelometer.
  • var_id: BSC_REDU
  • units: m-1
  • long_name: Uncorrected red total scattering coefficient from TSI 3563 nephelometer.
  • var_id: TSC_REDU
  • units: gram m-3
  • long_name: Uncorrected total condensed water content from the Nevzorov probe.
  • var_id: NV_TCW_U
  • standard_name:
  • units: m s-1
  • long_name: Upwards velocitiy from the XR5 GPS system.
  • var_id: GPS_VELZ
  • units: m s-1
  • standard_name: upward_air_velocity
  • long_name: Vertical wind component from turbulence probe and GIN
  • var_id: W_C
  • units: cm3 s-1
  • long_name: Volumetric sample flow rate through PCASP2 (SPP200)
  • var_id: PCAS2_FL
  • units: gram m-3
  • long_name: Water content from 2DC assuming ice
  • var_id: 2DC_IWC
  • units: gram m-3
  • long_name: Water content from 2DC assuming liquid
  • var_id: 2DC_LWC
  • units: cm-3
  • long_name: droplet concentration from PCASP2 (SPP200) channels 2 to 30 included
  • var_id: PCAS2CON
  • units: cm-3
  • long_name: droplet concentration in CDP size channel 1
  • var_id: CDP_01
  • units: cm-3
  • long_name: droplet concentration in CDP size channel 10
  • var_id: CDP_10
  • units: cm-3
  • long_name: droplet concentration in CDP size channel 11
  • var_id: CDP_11
  • units: cm-3
  • long_name: droplet concentration in CDP size channel 12
  • var_id: CDP_12
  • units: cm-3
  • long_name: droplet concentration in CDP size channel 13
  • var_id: CDP_13
  • units: cm-3
  • long_name: droplet concentration in CDP size channel 14
  • var_id: CDP_14
  • units: cm-3
  • long_name: droplet concentration in CDP size channel 15
  • var_id: CDP_15
  • units: cm-3
  • long_name: droplet concentration in CDP size channel 16
  • var_id: CDP_16
  • units: cm-3
  • long_name: droplet concentration in CDP size channel 17
  • var_id: CDP_17
  • units: cm-3
  • long_name: droplet concentration in CDP size channel 18
  • var_id: CDP_18
  • units: cm-3
  • long_name: droplet concentration in CDP size channel 19
  • var_id: CDP_19
  • units: cm-3
  • long_name: droplet concentration in CDP size channel 2
  • var_id: CDP_02
  • units: cm-3
  • long_name: droplet concentration in CDP size channel 20
  • var_id: CDP_20
  • units: cm-3
  • long_name: droplet concentration in CDP size channel 21
  • var_id: CDP_21
  • units: cm-3
  • long_name: droplet concentration in CDP size channel 22
  • var_id: CDP_22
  • units: cm-3
  • long_name: droplet concentration in CDP size channel 23
  • var_id: CDP_23
  • units: cm-3
  • long_name: droplet concentration in CDP size channel 24
  • var_id: CDP_24
  • units: cm-3
  • long_name: droplet concentration in CDP size channel 25
  • var_id: CDP_25
  • units: cm-3
  • long_name: droplet concentration in CDP size channel 26
  • var_id: CDP_26
  • units: cm-3
  • long_name: droplet concentration in CDP size channel 27
  • var_id: CDP_27
  • units: cm-3
  • long_name: droplet concentration in CDP size channel 28
  • var_id: CDP_28
  • units: cm-3
  • long_name: droplet concentration in CDP size channel 29
  • var_id: CDP_29
  • units: cm-3
  • long_name: droplet concentration in CDP size channel 3
  • var_id: CDP_03
  • units: cm-3
  • long_name: droplet concentration in CDP size channel 30
  • var_id: CDP_30
  • units: cm-3
  • long_name: droplet concentration in CDP size channel 4
  • var_id: CDP_04
  • units: cm-3
  • long_name: droplet concentration in CDP size channel 5
  • var_id: CDP_05
  • units: cm-3
  • long_name: droplet concentration in CDP size channel 6
  • var_id: CDP_06
  • units: cm-3
  • long_name: droplet concentration in CDP size channel 7
  • var_id: CDP_07
  • units: cm-3
  • long_name: droplet concentration in CDP size channel 8
  • var_id: CDP_08
  • units: cm-3
  • long_name: droplet concentration in CDP size channel 9
  • var_id: CDP_09
  • units: degree s-1
  • long_name: rate-of-change of GIN heading
  • standard_name: platform_yaw_rate
  • var_id: HDGR_GIN
  • units: degree s-1
  • long_name: rate-of-change of GIN pitch angle
  • standard_name: platform_roll_rate
  • var_id: PITR_GIN
  • units: degree s-1
  • long_name: rate-of-change of GIN roll angle
  • standard_name: platform_pitch_rate
  • var_id: ROLR_GIN
  • units: cm-3
  • long_name: total droplet concentration from CDP channels 2 to 30 included
  • var_id: CDP_CONC

Co-ordinate Variables

  • units: degree_north
  • standard_name: latitude
  • long_name: Latitude from POS AV 510 GPS-aided Inertial Navigation unit
  • var_id: LAT_GIN
  • units: degree_north
  • standard_name: latitude
  • long_name: Latitude from the XR5 GPS system.
  • var_id: LAT_GPS
  • units: degree_east
  • standard_name: longitude
  • long_name: Longitude from POS AV 510 GPS-aided Inertial Navigation unit
  • var_id: LON_GIN
  • units: degree_east
  • standard_name: longitude
  • long_name: Longitude from the XR5 GPS system.
  • var_id: LON_GPS
  • standard_name: time
  • long_name: Time UTC seconds past midnight for CDP
  • var_id: CDP_TSPM
  • standard_name: time
  • var_id: Time
  • long_name: time of measurement
Coverage
Temporal Range
Start time:
2010-09-28T06:43:06
End time:
2010-09-28T14:19:57
Geographic Extent

 
53.0237°
 
-0.6250°
 
1.6477°
 
52.0653°