This website uses cookies. By continuing to use this website you are agreeing to our use of cookies. 

Dataset

 

APHH: Online measurements of VOC mixing ratios using Gas Chromatography with Flame Ionisation Detector (GC-FID) at Indira Gandhi Delhi Technical University for Women (IGDTUW) field site during the DelhiFlux field campaign

Update Frequency: Not Planned
Latest Data Update: 2020-04-29
Status: Completed
Online Status: ONLINE
Publication State: Published
Publication Date: 2020-05-11
Download Stats: last 12 months
Dataset Size: 4 Files | 917KB

Abstract

This dataset contains hourly online measurements of VOC mixing ratios using Gas Chromatography with Flame Ionisation Detector (GC-FID) at Indira Gandhi Delhi Technical University for Women (IGDTUW), Dehli, India. Mixing ratios are reported in parts per billion by volume (ppbV). The stationary inlet was located on the roof of a single-story building. This data was collected
over two measurements periods (28/05/2018 - 05/06/2018 and 05/10/2018 - 27/10/2018), for the APHH-India DelhiFlux project, by the University of
York. Data analysis was completed by Beth Nelson and Jim Hopkins at the University of York.

Mixing ratios for the following species are included: ethane, ethene, propane, propane, iso-butane, n-butane, acetylene, trans-2-butene, 1-butene, iso-butene*, cis-2-butene, cyclopentane*, iso-pentane, n-pentane, 1,3-butadiene, trans-2-pentene, 1-pentene, n-octane, n-hexane, isoprene, n-heptane, benzene, toluene, ethylbenzene, combined m,p-xylene, o-xylene,
methanol, acetone, ethanol, 1,2-butadiene*, propyne*.

Date and time given in Local time as Julian day where 2018 01 01 = 0

Calibrations have been performed using a certified NPL 30 component mixture, and certified NPL 6 component mixture for o-VOC calibration. NOTE: any compound not contained therein has been assumed to have the same response factor as its closest isomer*.

The data were collected as part of the DelhiFlux project part of Air Pollution & Human Health in a Developing Indian Megacity (APHH-India) programme.

Citable as:  Nelson, B.; Hopkins, J.R.; Stewart, G.; Dunmore, R.; Hamilton, J.F. (2020): APHH: Online measurements of VOC mixing ratios using Gas Chromatography with Flame Ionisation Detector (GC-FID) at Indira Gandhi Delhi Technical University for Women (IGDTUW) field site during the DelhiFlux field campaign. Centre for Environmental Data Analysis, date of citation. https://catalogue.ceda.ac.uk/uuid/fae65a63910a44b28a3d91268417b7c3
Abbreviation: Not defined
Keywords: APHH, Delhiflux, VOC

Details

Previous Info:
No news update for this record
Previously used record identifiers:
No related previous identifiers.
Access rules:
Restricted data: please submit an application using the REQUEST ACCESS link for access.
Use of these data is covered by the following licence: http://licences.ceda.ac.uk/image/data_access_condition/APHH-Delhi-conditions.pdf. When using these data you must cite them correctly using the citation given on the CEDA Data Catalogue record.
Data lineage:

Data collected at IGDTUW by Beth Nelson, Gareth Stewart and Jim Hopkins from the University of York. Analysis of data completed by Beth Nelson and Jim Hopkins. Resource uploaded to archive by Beth Nelson.

Data Quality:
Calibrations have been performed using a certified NPL 30 component mixture. o-VOCs calibrated using NPL 6 component mixture.
File Format:
Data are NASA Ames formatted.

Related Documents

No documents related to this record were found.

Process overview

This dataset was generated by instruments deployed on platforms as listed below.
Output Description

None

Co-ordinate Variables

Coverage
Temporal Range
Start time:
2018-05-28T00:00:00
End time:
2018-10-27T00:00:00
Geographic Extent

 
28.6640°
 
77.2320°
 
77.2320°
 
28.6640°