NERC Mesosphere-Stratosphere-Troposphere (MST) Radar Facility: Surface Meteorological Data, Capel Dewi site, Wales

Update Frequency: Daily
Latest Data Update: 2023-06-19
Status: Ongoing
Online Status: ONLINE
Publication State: Published
Publication Date: 2007-03-15
Download Stats: last 12 months
Dataset Size: 8.42K Files | 105MB

Abstract

Surface meteorological data are measured by a number of instruments deployed at the Natural Environment Research Council's (NERC) Mesosphere-Stratosphere-Troposphere (MST) Radar Facility, Capel Dewi, near Aberystwyth in West Wales. This dataset consists of data collected by the following suite instruments connected to a Campbell Scientific CR10 Climate Data Logger: Campbell Scientific 107 thermistor temperature probe mounted inside an URS1 unaspirated radiation shield. Accuracy: +/- 0.4 degrees C. Vaisala PTB101B barometric pressure sensor. Accuracy: +/- 2.0 hPa. Vaisala HMP45C temperature and relative humidity probe (from which only the humidity measurements are used) mounted inside an URS1 un-aspirated radiation shield. Accuracy: +/- 0.3%. Environmental Measurements ARG100 tipping bucket raingauge. Kipp and Zonen CM3 thermopile pyranometer (WMO second class). Accuracy: +/- 0.5%. The raingauge is located on the ground. All other sensors are mounted on a post approximately 1 m above the ground.

The data logger initially samples the atmospheric temperature, pressure and humidity sensors at 5 s intervals. Mean values are calculated over each 60 s and the outputs from the logger represent minima, means and maxima of these 60 s means over each 10 minute sample period. The data logger is connected to a tipping bucket raingauge (sampled every 1 s, and recording tips for each 0.20 mm accumulation of rain); pyranometer (sampled every every 5 s, recording the down-welling radiation within a hemispheric field of view with a flat response in the spectral range 305 - 2800 nm);

The data are available in NASA-Ames formatted files.

Independent surface meteorological data are also available from the Vaisala WXT510 instrument also located at the site and are available in the wxt510-precipitation and PTU datasets.

Citable as:  Natural Environment Research Council Mesosphere-Stratosphere-Troposphere Radar Facility at Aberystwyth; Hooper, D.A. (2007): NERC Mesosphere-Stratosphere-Troposphere (MST) Radar Facility: Surface Meteorological Data, Capel Dewi site, Wales. NCAS British Atmospheric Data Centre, date of citation. https://catalogue.ceda.ac.uk/uuid/51234b47e27aa55e50f8e2eb44927c1e/
Abbreviation: Not defined
Keywords: MST, meteorology, surface, 2m, pressure, temperature, humidity

Details

Previous Info:
No news update for this record
Previously used record identifiers:
http://badc.nerc.ac.uk/view/badc.nerc.ac.uk__ATOM__dep_11740027524717750
Access rules:
Access to these data is available to any registered CEDA user. Please Login or Register for a CEDA account to gain access.
Use of these data is covered by the following licence(s):
https://artefacts.ceda.ac.uk/licences/missing_licence.pdf
When using these data you must cite them correctly using the citation given on the CEDA Data Catalogue record.
Data lineage:

Data are acquired by the MST radar facility and sent to the BADC within an hour of acquisition. Data are then immediately ingested into the BADC archives.

Data Quality:
The MST radar data quality is described by D. A. Hooper, J. Nash, T. Oakley, and M. Turp. Validation of a new signal processing scheme for the MST radar at Aberystwyth. Ann. Geophys., 26(11):3253-3268, 2008. (available from here http://www.ann-geophys.net/26/3253/2008/angeo-26-3253-2008.html)
File Format:
Data are available in NASA-Ames formatted files.

Process overview

This dataset was generated by instruments deployed on platforms as listed below.
Output Description

None

  • units: kJ m-2
  • names: Accumulated downwelling shortwave energy per unit area within 10 minute sample period
  • units: mm
  • names: Accumulated rainfall within 10 minute sample period
  • units: V
  • names: Data logger battery voltage at end of 10 minute sample period
  • units: degrees C
  • names: Data logger internal temperature at end of 10 minute sample period
  • units: hours
  • names: Estimated duration of sunshine within 10 minute sample period
  • units: degrees C
  • names: Maximum air temperature within 10 minute sample period
  • units: hPa
  • names: Mean air pressure within 10 minute sample period
  • units: None
  • names: Mean air relative humidity within 10 minute sample period
  • units: degrees C
  • names: Mean air temperature within 10 minute sample period
  • units: degrees C
  • names: Minimum air temperature within 10 minute sample period
  • long_name: Rainfall Tip Count
  • names: Rainfall Tip Count

Co-ordinate Variables

Coverage
Temporal Range
Start time:
2000-07-24T23:00:00
End time:
Ongoing
Geographic Extent

 
52.4245°
 
-4.0055°
 
-4.0055°
 
52.4245°