FAAM B600 FENNEC flight: Airborne atmospheric measurements from core and non-core instrument suites on board the BAE-146 aircraft

Update Frequency: Not Planned
Latest Data Update: 2015-04-30
Status: Completed
Online Status: ONLINE
Publication State: Published
Publication Date: 2014-07-14
Download Stats: last 12 months
Dataset Size: 37 Files | 1GB

Abstract

Airborne atmospheric measurements from core and non-core instrument suites data on board the FAAM BAE-146 aircraft collected for Fennec - The Saharan Climate System (FENNEC) project.

Citable as:  Facility for Airborne Atmospheric Measurements; Natural Environment Research Council; Met Office (2014): FAAM B600 FENNEC flight: Airborne atmospheric measurements from core and non-core instrument suites on board the BAE-146 aircraft. NCAS British Atmospheric Data Centre, date of citation. https://catalogue.ceda.ac.uk/uuid/77ec7d4621fb49c4b6618c80ff90aa72/
Abbreviation: Not defined
Keywords: FENNEC, FAAM, airborne, atmospheric measurments

Details

Previous Info:
No news update for this record
Previously used record identifiers:
No related previous identifiers.
Access rules:
Access to these data is available to any registered CEDA user. Please Login or Register for a CEDA account to gain access.
Use of these data is covered by the following licence(s):
http://www.nationalarchives.gov.uk/doc/open-government-licence/version/3/
When using these data you must cite them correctly using the citation given on the CEDA Data Catalogue record.
Data lineage:

Data were collected by instrument scientists during the flight before preparation and delivery for archiving at the NCAS British Atmospheric Data Centre.

Data Quality:
Data collected by flight participants before preparation for archival with the British Atmospheric Data Centre
File Format:
Data are netCDF and NASA-Ames formatted. Ancillary files may be plain ASCII or PDF formatted. Image files may be PNG formatted.
  • var_id: ARIESRAD
  • var_id: CALIBRATION_FILES
  • var_id: CAL_DC_CBB
  • var_id: CAL_DC_HBB
  • var_id: CAL_DC_MEAS
  • var_id: CAL_TEMP_CBB
  • var_id: CAL_TEMP_HBB
  • var_id: CAL_TEMP_PORT2C
  • var_id: CAL_TEMP_PORT2H
  • units: g m-3
  • long_name: CAS Liquid Water Content
  • var_id: CAS_LWC
  • units: cm-3
  • long_name: CAS Total Concentation
  • var_id: CAS_TC
  • units: um
  • long_name: CAS bin edges (uncorrected)
  • var_id: CAS_Bin
  • long_name: CDP Channel Number
  • var_id: CDPCH
  • units:
  • units: micron
  • long_name: Calibrated channel diameter lower limits
  • var_id: PCAS2_D_L_CAL
  • units: micron
  • long_name: Calibrated channel diameter upper limits
  • var_id: PCAS2_D_U_CAL
  • long_name: Composition of the aerosol used to calibrate channel diameter lower limits
  • var_id: PCAS2_D_L_COMP
  • units:
  • long_name: Composition of the aerosol used to calibrate channel diameter upper limits
  • var_id: PCAS2_D_U_COMP
  • units:
  • units: micron
  • long_name: Error in calibrated channel diameter lower limits
  • var_id: PCAS2_D_L_ERR
  • units: micron
  • long_name: Error in calibrated channel diameter upper limits
  • var_id: PCAS2_D_U_ERR
  • long_name: Flag for droplet concentration from CDP channels 2 to 30 included
  • var_id: CDP_FLAG
  • units:
  • long_name: Flag for droplet concentration from PCASP2 (SPP200) channels 2 to 30 included
  • var_id: PCAS2_FLAG
  • units:
  • var_id: LONG_DATE
  • units: micron
  • long_name: Nominal uncalibrated channel diameter lower limits as given in the instrument manual
  • var_id: PCAS2_D_L_NOM
  • units: micron
  • long_name: Nominal uncalibrated channel diameter upper limits as given in the instrument manual
  • var_id: PCAS2_D_U_NOM
  • long_name: PCASP (SPP200) Channel Number
  • var_id: PCAS2CH
  • units:
  • units: cm-3
  • long_name: PCASP2 (SPP200) conc in size channel 1
  • var_id: PCAS2_01
  • units: cm-3
  • long_name: PCASP2 (SPP200) conc in size channel 10
  • var_id: PCAS2_10
  • units: cm-3
  • long_name: PCASP2 (SPP200) conc in size channel 11
  • var_id: PCAS2_11
  • units: cm-3
  • long_name: PCASP2 (SPP200) conc in size channel 12
  • var_id: PCAS2_12
  • units: cm-3
  • long_name: PCASP2 (SPP200) conc in size channel 13
  • var_id: PCAS2_13
  • units: cm-3
  • long_name: PCASP2 (SPP200) conc in size channel 14
  • var_id: PCAS2_14
  • units: cm-3
  • long_name: PCASP2 (SPP200) conc in size channel 15
  • var_id: PCAS2_15
  • units: cm-3
  • long_name: PCASP2 (SPP200) conc in size channel 16
  • var_id: PCAS2_16
  • units: cm-3
  • long_name: PCASP2 (SPP200) conc in size channel 17
  • var_id: PCAS2_17
  • units: cm-3
  • long_name: PCASP2 (SPP200) conc in size channel 18
  • var_id: PCAS2_18
  • units: cm-3
  • long_name: PCASP2 (SPP200) conc in size channel 19
  • var_id: PCAS2_19
  • units: cm-3
  • long_name: PCASP2 (SPP200) conc in size channel 2
  • var_id: PCAS2_02
  • units: cm-3
  • long_name: PCASP2 (SPP200) conc in size channel 20
  • var_id: PCAS2_20
  • units: cm-3
  • long_name: PCASP2 (SPP200) conc in size channel 21
  • var_id: PCAS2_21
  • units: cm-3
  • long_name: PCASP2 (SPP200) conc in size channel 22
  • var_id: PCAS2_22
  • units: cm-3
  • long_name: PCASP2 (SPP200) conc in size channel 23
  • var_id: PCAS2_23
  • units: cm-3
  • long_name: PCASP2 (SPP200) conc in size channel 24
  • var_id: PCAS2_24
  • units: cm-3
  • long_name: PCASP2 (SPP200) conc in size channel 25
  • var_id: PCAS2_25
  • units: cm-3
  • long_name: PCASP2 (SPP200) conc in size channel 26
  • var_id: PCAS2_26
  • units: cm-3
  • long_name: PCASP2 (SPP200) conc in size channel 27
  • var_id: PCAS2_27
  • units: cm-3
  • long_name: PCASP2 (SPP200) conc in size channel 28
  • var_id: PCAS2_28
  • units: cm-3
  • long_name: PCASP2 (SPP200) conc in size channel 29
  • var_id: PCAS2_29
  • units: cm-3
  • long_name: PCASP2 (SPP200) conc in size channel 3
  • var_id: PCAS2_03
  • units: cm-3
  • long_name: PCASP2 (SPP200) conc in size channel 30
  • var_id: PCAS2_30
  • units: cm-3
  • long_name: PCASP2 (SPP200) conc in size channel 4
  • var_id: PCAS2_04
  • units: cm-3
  • long_name: PCASP2 (SPP200) conc in size channel 5
  • var_id: PCAS2_05
  • units: cm-3
  • long_name: PCASP2 (SPP200) conc in size channel 6
  • var_id: PCAS2_06
  • units: cm-3
  • long_name: PCASP2 (SPP200) conc in size channel 7
  • var_id: PCAS2_07
  • units: cm-3
  • long_name: PCASP2 (SPP200) conc in size channel 8
  • var_id: PCAS2_08
  • units: cm-3
  • long_name: PCASP2 (SPP200) conc in size channel 9
  • var_id: PCAS2_09
  • units: percent
  • long_name: Percentage error in PCASP2 (SPP200) conc in size channel 1
  • var_id: PCAS2_01_err
  • units: percent
  • long_name: Percentage error in PCASP2 (SPP200) conc in size channel 10
  • var_id: PCAS2_10_err
  • units: percent
  • long_name: Percentage error in PCASP2 (SPP200) conc in size channel 11
  • var_id: PCAS2_11_err
  • units: percent
  • long_name: Percentage error in PCASP2 (SPP200) conc in size channel 12
  • var_id: PCAS2_12_err
  • units: percent
  • long_name: Percentage error in PCASP2 (SPP200) conc in size channel 13
  • var_id: PCAS2_13_err
  • units: percent
  • long_name: Percentage error in PCASP2 (SPP200) conc in size channel 14
  • var_id: PCAS2_14_err
  • units: percent
  • long_name: Percentage error in PCASP2 (SPP200) conc in size channel 15
  • var_id: PCAS2_15_err
  • units: percent
  • long_name: Percentage error in PCASP2 (SPP200) conc in size channel 16
  • var_id: PCAS2_16_err
  • units: percent
  • long_name: Percentage error in PCASP2 (SPP200) conc in size channel 17
  • var_id: PCAS2_17_err
  • units: percent
  • long_name: Percentage error in PCASP2 (SPP200) conc in size channel 18
  • var_id: PCAS2_18_err
  • units: percent
  • long_name: Percentage error in PCASP2 (SPP200) conc in size channel 19
  • var_id: PCAS2_19_err
  • units: percent
  • long_name: Percentage error in PCASP2 (SPP200) conc in size channel 2
  • var_id: PCAS2_02_err
  • units: percent
  • long_name: Percentage error in PCASP2 (SPP200) conc in size channel 20
  • var_id: PCAS2_20_err
  • units: percent
  • long_name: Percentage error in PCASP2 (SPP200) conc in size channel 21
  • var_id: PCAS2_21_err
  • units: percent
  • long_name: Percentage error in PCASP2 (SPP200) conc in size channel 22
  • var_id: PCAS2_22_err
  • units: percent
  • long_name: Percentage error in PCASP2 (SPP200) conc in size channel 23
  • var_id: PCAS2_23_err
  • units: percent
  • long_name: Percentage error in PCASP2 (SPP200) conc in size channel 24
  • var_id: PCAS2_24_err
  • units: percent
  • long_name: Percentage error in PCASP2 (SPP200) conc in size channel 25
  • var_id: PCAS2_25_err
  • units: percent
  • long_name: Percentage error in PCASP2 (SPP200) conc in size channel 26
  • var_id: PCAS2_26_err
  • units: percent
  • long_name: Percentage error in PCASP2 (SPP200) conc in size channel 27
  • var_id: PCAS2_27_err
  • units: percent
  • long_name: Percentage error in PCASP2 (SPP200) conc in size channel 28
  • var_id: PCAS2_28_err
  • units: percent
  • long_name: Percentage error in PCASP2 (SPP200) conc in size channel 29
  • var_id: PCAS2_29_err
  • units: percent
  • long_name: Percentage error in PCASP2 (SPP200) conc in size channel 3
  • var_id: PCAS2_03_err
  • units: percent
  • long_name: Percentage error in PCASP2 (SPP200) conc in size channel 30
  • var_id: PCAS2_30_err
  • units: percent
  • long_name: Percentage error in PCASP2 (SPP200) conc in size channel 4
  • var_id: PCAS2_04_err
  • units: percent
  • long_name: Percentage error in PCASP2 (SPP200) conc in size channel 5
  • var_id: PCAS2_05_err
  • units: percent
  • long_name: Percentage error in PCASP2 (SPP200) conc in size channel 6
  • var_id: PCAS2_06_err
  • units: percent
  • long_name: Percentage error in PCASP2 (SPP200) conc in size channel 7
  • var_id: PCAS2_07_err
  • units: percent
  • long_name: Percentage error in PCASP2 (SPP200) conc in size channel 8
  • var_id: PCAS2_08_err
  • units: percent
  • long_name: Percentage error in PCASP2 (SPP200) conc in size channel 9
  • var_id: PCAS2_09_err
  • var_id: QUALITY
  • long_name: Refractive index of the aerosol used to calibrate channel diameter lower limits
  • var_id: PCAS2_D_L_RI
  • units:
  • long_name: Refractive index of the aerosol used to calibrate channel diameter upper limits
  • var_id: PCAS2_D_U_RI
  • units:
  • var_id: SCANDIR
  • var_id: SECONDS
  • units: cm-1
  • long_name: Size distribution from the CAS (forward scatter)
  • var_id: CAS_binconcs
  • units: m s-1
  • var_id: TAS
  • long_name: TAS used for sample volume (CAPS PITOT)
  • var_id: Time
  • long_name: Time UTC integer seconds past midnight
  • long_name: Time UTC seconds past midnight for PCASP2 (SPP200)
  • standard_name: Time
  • var_id: PCAS2TSPM
  • units: cm3 s-1
  • long_name: Volumetric sample flow rate through PCASP2 (SPP200)
  • var_id: PCAS2_FL
  • var_id: WAVENUM
  • var_id: ZPD_POSITION
  • var_id: alt
  • units: meters
  • long_name: altitude above MSL
  • units: degC
  • long_name: dp
  • var_id: dp
  • units: cm-3
  • long_name: droplet concentration from PCASP2 (SPP200) channels 2 to 30 included
  • var_id: PCAS2CON
  • units: cm-3
  • long_name: droplet concentration in CDP size channel 1
  • var_id: CDP_01
  • units: cm-3
  • long_name: droplet concentration in CDP size channel 10
  • var_id: CDP_10
  • units: cm-3
  • long_name: droplet concentration in CDP size channel 11
  • var_id: CDP_11
  • units: cm-3
  • long_name: droplet concentration in CDP size channel 12
  • var_id: CDP_12
  • units: cm-3
  • long_name: droplet concentration in CDP size channel 13
  • var_id: CDP_13
  • units: cm-3
  • long_name: droplet concentration in CDP size channel 14
  • var_id: CDP_14
  • units: cm-3
  • long_name: droplet concentration in CDP size channel 15
  • var_id: CDP_15
  • units: cm-3
  • long_name: droplet concentration in CDP size channel 16
  • var_id: CDP_16
  • units: cm-3
  • long_name: droplet concentration in CDP size channel 17
  • var_id: CDP_17
  • units: cm-3
  • long_name: droplet concentration in CDP size channel 18
  • var_id: CDP_18
  • units: cm-3
  • long_name: droplet concentration in CDP size channel 19
  • var_id: CDP_19
  • units: cm-3
  • long_name: droplet concentration in CDP size channel 2
  • var_id: CDP_02
  • units: cm-3
  • long_name: droplet concentration in CDP size channel 20
  • var_id: CDP_20
  • units: cm-3
  • long_name: droplet concentration in CDP size channel 21
  • var_id: CDP_21
  • units: cm-3
  • long_name: droplet concentration in CDP size channel 22
  • var_id: CDP_22
  • units: cm-3
  • long_name: droplet concentration in CDP size channel 23
  • var_id: CDP_23
  • units: cm-3
  • long_name: droplet concentration in CDP size channel 24
  • var_id: CDP_24
  • units: cm-3
  • long_name: droplet concentration in CDP size channel 25
  • var_id: CDP_25
  • units: cm-3
  • long_name: droplet concentration in CDP size channel 26
  • var_id: CDP_26
  • units: cm-3
  • long_name: droplet concentration in CDP size channel 27
  • var_id: CDP_27
  • units: cm-3
  • long_name: droplet concentration in CDP size channel 28
  • var_id: CDP_28
  • units: cm-3
  • long_name: droplet concentration in CDP size channel 29
  • var_id: CDP_29
  • units: cm-3
  • long_name: droplet concentration in CDP size channel 3
  • var_id: CDP_03
  • units: cm-3
  • long_name: droplet concentration in CDP size channel 30
  • var_id: CDP_30
  • units: cm-3
  • long_name: droplet concentration in CDP size channel 4
  • var_id: CDP_04
  • units: cm-3
  • long_name: droplet concentration in CDP size channel 5
  • var_id: CDP_05
  • units: cm-3
  • long_name: droplet concentration in CDP size channel 6
  • var_id: CDP_06
  • units: cm-3
  • long_name: droplet concentration in CDP size channel 7
  • var_id: CDP_07
  • units: cm-3
  • long_name: droplet concentration in CDP size channel 8
  • var_id: CDP_08
  • units: cm-3
  • long_name: droplet concentration in CDP size channel 9
  • var_id: CDP_09
  • units: K
  • long_name: dry nephelometer sample inlet temperature
  • var_id: tin_dry
  • units: K
  • long_name: dry nephelometer sample outlet temperature
  • var_id: tout_dry
  • units: hPa
  • long_name: dry nephelometer sample pressure
  • var_id: p_dry
  • units: %
  • long_name: dry nephelometer sample relative humidity
  • var_id: rh_dry
  • units: m/s
  • long_name: dz
  • var_id: dz
  • units: degrees
  • var_id: lon
  • long_name: east longitude
  • units: degC
  • long_name: humidifier water temperature
  • var_id: t_water
  • units: gram/kg
  • long_name: mr
  • var_id: mr
  • units: degrees
  • var_id: lat
  • long_name: north latitude
  • units: hPa
  • var_id: pres
  • long_name: pres
  • units: hPa
  • long_name: qp
  • var_id: qp
  • units: percent
  • long_name: qrh
  • var_id: qrh
  • units: degC
  • long_name: qt
  • var_id: qt
  • units: m/s
  • long_name: qu
  • var_id: qu
  • units: m/s
  • long_name: qv
  • var_id: qv
  • units: m/s
  • long_name: qwind
  • var_id: qwind
  • var_id: range
  • units: km
  • long_name: range
  • units: %
  • long_name: relative humidity sensor 1
  • var_id: rh1
  • units: %
  • long_name: relative humidity sensor 2
  • var_id: rh2
  • units: %
  • long_name: relative humidity sensor 3
  • var_id: rh3
  • units: %
  • long_name: relative humidity sensor 4
  • var_id: rh4
  • units: %
  • long_name: relative humidity sensor 5
  • var_id: rh5
  • units: %
  • long_name: relative humidity sensor 6
  • var_id: rh6
  • units: percent
  • var_id: rh
  • long_name: rh
  • units: L min-1
  • long_name: sample flow rate
  • var_id: flow
  • units: seconds
  • long_name: seconds since base_time
  • var_id: time_offset
  • long_name: sounding launch time
  • var_id: base_time
  • units: degC
  • long_name: tdry
  • var_id: tdry
  • units: degC
  • long_name: temperature sensor 1
  • var_id: t1
  • units: degC
  • var_id: t2
  • long_name: temperature sensor 2
  • units: degC
  • long_name: temperature sensor 3
  • var_id: t3
  • units: degC
  • long_name: temperature sensor 4
  • var_id: t4
  • units: K
  • var_id: theta
  • long_name: theta
  • units: K
  • long_name: theta_e
  • var_id: theta_e
  • units: K
  • long_name: theta_v
  • var_id: theta_v
  • long_name: time
  • var_id: time
  • units: cm-3
  • long_name: total droplet concentration from CDP channels 2 to 30 included
  • var_id: CDP_CONC
  • units: m/s
  • long_name: u_wind
  • var_id: u_wind
  • units: m-1
  • long_name: uncorrected dry nephelometer blue 0.45 micron total scattering coefficient
  • var_id: b_dry
  • units: m-1
  • long_name: uncorrected dry nephelometer green 0.55 micron total scattering coefficient
  • var_id: g_dry
  • units: m-1
  • long_name: uncorrected dry nephelometer red 0.70 micron total scattering coefficient
  • var_id: r_dry
  • units: m-1
  • long_name: uncorrected wet nephelometer blue 0.45 micron total scattering coefficient
  • var_id: b_wet
  • units: m-1
  • long_name: uncorrected wet nephelometer green 0.55 micron total scattering coefficient
  • var_id: g_wet
  • units: m-1
  • long_name: uncorrected wet nephelometer red 0.70 micron total scattering coefficient
  • var_id: r_wet
  • units: m/s
  • long_name: v_wind
  • var_id: v_wind
  • units: degC
  • long_name: vt
  • var_id: vt
  • units: degree
  • var_id: wdir
  • long_name: wdir
  • units: K
  • long_name: wet nephelometer sample inlet temperature
  • var_id: tin_wet
  • units: K
  • long_name: wet nephelometer sample outlet temperature
  • var_id: tout_wet
  • units: hPa
  • long_name: wet nephelometer sample pressure
  • var_id: p_wet
  • units: %
  • long_name: wet nephelometer sample relative humidity
  • var_id: rh_wet
  • units: m/s
  • var_id: wspd
  • long_name: wspd

Co-ordinate Variables

  • standard_name: time
  • long_name: Time UTC seconds past midnight for CDP
  • var_id: CDP_TSPM
  • standard_name: time
  • var_id: time
  • units: s
  • long_name: Time stamp from the CAS (seconds since midnight)
  • standard_name: time
  • var_id: Time
  • long_name: time of measurement
Coverage
Temporal Range
Start time:
2011-06-17T05:17:25
End time:
2011-06-17T12:05:40
Geographic Extent

 
28.5507°
 
-13.8743°
 
-4.3737°
 
21.9268°