Dataset

 

FAAM B445 MEVEX flight, D4: Airborne atmospheric measurements from core and non-core instrument suites on board the BAE-146 aircraft

Update Frequency: As Needed
Latest Data Update: 2015-04-30
Status: Completed
Online Status: ONLINE
Publication State: Published
Publication Date: 2014-07-11
Download Stats: last 12 months
Dataset Size: 62 Files | 6GB

Abstract

Airborne atmospheric measurements from core and non-core instrument suites data on board the FAAM BAE-146 aircraft, D4 flight for MEVEX - Middle East Validation EXperiment project.

Citable as:  Facility for Airborne Atmospheric Measurements; Natural Environment Research Council; Met Office (2014): FAAM B445 MEVEX flight, D4: Airborne atmospheric measurements from core and non-core instrument suites on board the BAE-146 aircraft. NCAS British Atmospheric Data Centre, date of citation. https://catalogue.ceda.ac.uk/uuid/b254dd39a36841bbb5698002c70d6115/
Abbreviation: Not defined
Keywords: MEVEX, FAAM, airborne, atmospheric measurments

Details

Previous Info:
No news update for this record
Previously used record identifiers:
No related previous identifiers.
Access rules:
Access to these data is available to any registered CEDA user. Please Login or Register for a CEDA account to gain access.
Use of these data is covered by the following licence(s):
http://www.nationalarchives.gov.uk/doc/open-government-licence/version/3/
When using these data you must cite them correctly using the citation given on the CEDA Data Catalogue record.
Data lineage:

Data were collected by instrument scientists during the flight before preparation and delivery for archiving at the NCAS British Atmospheric Data Centre.

Data Quality:
Data collected by flight participants before preparation for archival with the British Atmospheric Data Centre
File Format:
Data are netCDF and NASA-Ames formatted. Ancillary files may be plain ASCII or PDF formatted. Image files may be PNG formatted.
  • units: m-3
  • long_name: 2DC Concentration in size channel 0
  • var_id: 2DC_CH00
  • units: m-3
  • long_name: 2DC Concentration in size channel 1
  • var_id: 2DC_CH01
  • units: m-3
  • long_name: 2DC Concentration in size channel 10
  • var_id: 2DC_CH10
  • units: m-3
  • long_name: 2DC Concentration in size channel 11
  • var_id: 2DC_CH11
  • units: m-3
  • long_name: 2DC Concentration in size channel 12
  • var_id: 2DC_CH12
  • units: m-3
  • long_name: 2DC Concentration in size channel 13
  • var_id: 2DC_CH13
  • units: m-3
  • long_name: 2DC Concentration in size channel 14
  • var_id: 2DC_CH14
  • units: m-3
  • long_name: 2DC Concentration in size channel 15
  • var_id: 2DC_CH15
  • units: m-3
  • long_name: 2DC Concentration in size channel 16
  • var_id: 2DC_CH16
  • units: m-3
  • long_name: 2DC Concentration in size channel 17
  • var_id: 2DC_CH17
  • units: m-3
  • long_name: 2DC Concentration in size channel 18
  • var_id: 2DC_CH18
  • units: m-3
  • long_name: 2DC Concentration in size channel 19
  • var_id: 2DC_CH19
  • units: m-3
  • long_name: 2DC Concentration in size channel 2
  • var_id: 2DC_CH02
  • units: m-3
  • long_name: 2DC Concentration in size channel 20
  • var_id: 2DC_CH20
  • units: m-3
  • long_name: 2DC Concentration in size channel 21
  • var_id: 2DC_CH21
  • units: m-3
  • long_name: 2DC Concentration in size channel 22
  • var_id: 2DC_CH22
  • units: m-3
  • long_name: 2DC Concentration in size channel 23
  • var_id: 2DC_CH23
  • units: m-3
  • long_name: 2DC Concentration in size channel 24
  • var_id: 2DC_CH24
  • units: m-3
  • long_name: 2DC Concentration in size channel 25
  • var_id: 2DC_CH25
  • units: m-3
  • long_name: 2DC Concentration in size channel 26
  • var_id: 2DC_CH26
  • units: m-3
  • long_name: 2DC Concentration in size channel 27
  • var_id: 2DC_CH27
  • units: m-3
  • long_name: 2DC Concentration in size channel 28
  • var_id: 2DC_CH28
  • units: m-3
  • long_name: 2DC Concentration in size channel 29
  • var_id: 2DC_CH29
  • units: m-3
  • long_name: 2DC Concentration in size channel 3
  • var_id: 2DC_CH03
  • units: m-3
  • long_name: 2DC Concentration in size channel 30
  • var_id: 2DC_CH30
  • units: m-3
  • long_name: 2DC Concentration in size channel 31
  • var_id: 2DC_CH31
  • units: m-3
  • long_name: 2DC Concentration in size channel 4
  • var_id: 2DC_CH04
  • units: m-3
  • long_name: 2DC Concentration in size channel 5
  • var_id: 2DC_CH05
  • units: m-3
  • long_name: 2DC Concentration in size channel 6
  • var_id: 2DC_CH06
  • units: m-3
  • long_name: 2DC Concentration in size channel 7
  • var_id: 2DC_CH07
  • units: m-3
  • long_name: 2DC Concentration in size channel 8
  • var_id: 2DC_CH08
  • units: m-3
  • long_name: 2DC Concentration in size channel 9
  • var_id: 2DC_CH09
  • var_id: ARIESRAD
  • units: degK
  • long_name: Brightness Temperature
  • var_id: bt
  • var_id: CALIBRATION_FILES
  • var_id: CAL_DC_CBB
  • var_id: CAL_DC_HBB
  • var_id: CAL_DC_MEAS
  • var_id: CAL_TEMP_CBB
  • var_id: CAL_TEMP_HBB
  • var_id: CAL_TEMP_PORT2C
  • var_id: CAL_TEMP_PORT2H
  • units: 1
  • long_name: Data Quality Flags
  • var_id: allflags
  • units: 1
  • long_name: Flag for 2DC Concentration in size channel 0
  • var_id: 2DC_CH00_FLAG
  • units: 1
  • long_name: Flag for 2DC Concentration in size channel 1
  • var_id: 2DC_CH01_FLAG
  • units: 1
  • long_name: Flag for 2DC Concentration in size channel 10
  • var_id: 2DC_CH10_FLAG
  • units: 1
  • long_name: Flag for 2DC Concentration in size channel 11
  • var_id: 2DC_CH11_FLAG
  • units: 1
  • long_name: Flag for 2DC Concentration in size channel 12
  • var_id: 2DC_CH12_FLAG
  • units: 1
  • long_name: Flag for 2DC Concentration in size channel 13
  • var_id: 2DC_CH13_FLAG
  • units: 1
  • long_name: Flag for 2DC Concentration in size channel 14
  • var_id: 2DC_CH14_FLAG
  • units: 1
  • long_name: Flag for 2DC Concentration in size channel 15
  • var_id: 2DC_CH15_FLAG
  • units: 1
  • long_name: Flag for 2DC Concentration in size channel 16
  • var_id: 2DC_CH16_FLAG
  • units: 1
  • long_name: Flag for 2DC Concentration in size channel 17
  • var_id: 2DC_CH17_FLAG
  • units: 1
  • long_name: Flag for 2DC Concentration in size channel 18
  • var_id: 2DC_CH18_FLAG
  • units: 1
  • long_name: Flag for 2DC Concentration in size channel 19
  • var_id: 2DC_CH19_FLAG
  • units: 1
  • long_name: Flag for 2DC Concentration in size channel 2
  • var_id: 2DC_CH02_FLAG
  • units: 1
  • long_name: Flag for 2DC Concentration in size channel 20
  • var_id: 2DC_CH20_FLAG
  • units: 1
  • long_name: Flag for 2DC Concentration in size channel 21
  • var_id: 2DC_CH21_FLAG
  • units: 1
  • long_name: Flag for 2DC Concentration in size channel 22
  • var_id: 2DC_CH22_FLAG
  • units: 1
  • long_name: Flag for 2DC Concentration in size channel 23
  • var_id: 2DC_CH23_FLAG
  • units: 1
  • long_name: Flag for 2DC Concentration in size channel 24
  • var_id: 2DC_CH24_FLAG
  • units: 1
  • long_name: Flag for 2DC Concentration in size channel 25
  • var_id: 2DC_CH25_FLAG
  • units: 1
  • long_name: Flag for 2DC Concentration in size channel 26
  • var_id: 2DC_CH26_FLAG
  • units: 1
  • long_name: Flag for 2DC Concentration in size channel 27
  • var_id: 2DC_CH27_FLAG
  • units: 1
  • long_name: Flag for 2DC Concentration in size channel 28
  • var_id: 2DC_CH28_FLAG
  • units: 1
  • long_name: Flag for 2DC Concentration in size channel 29
  • var_id: 2DC_CH29_FLAG
  • units: 1
  • long_name: Flag for 2DC Concentration in size channel 3
  • var_id: 2DC_CH03_FLAG
  • units: 1
  • long_name: Flag for 2DC Concentration in size channel 30
  • var_id: 2DC_CH30_FLAG
  • units: 1
  • long_name: Flag for 2DC Concentration in size channel 31
  • var_id: 2DC_CH31_FLAG
  • units: 1
  • long_name: Flag for 2DC Concentration in size channel 4
  • var_id: 2DC_CH04_FLAG
  • units: 1
  • long_name: Flag for 2DC Concentration in size channel 5
  • var_id: 2DC_CH05_FLAG
  • units: 1
  • long_name: Flag for 2DC Concentration in size channel 6
  • var_id: 2DC_CH06_FLAG
  • units: 1
  • long_name: Flag for 2DC Concentration in size channel 7
  • var_id: 2DC_CH07_FLAG
  • units: 1
  • long_name: Flag for 2DC Concentration in size channel 8
  • var_id: 2DC_CH08_FLAG
  • units: 1
  • long_name: Flag for 2DC Concentration in size channel 9
  • var_id: 2DC_CH09_FLAG
  • units: 1
  • long_name: Flag for Ice water content from 2DC
  • var_id: 2DC_IWC_FLAG
  • units: 1
  • long_name: Flag for Liquid water content from 2DC
  • var_id: 2DC_LWC_FLAG
  • units: 1
  • long_name: Flag for Mass content from PCASP
  • var_id: PCASPMAS_FLAG
  • units: 1
  • long_name: Flag for PCASP Concentration in size channel 0
  • var_id: PCASP_00_FLAG
  • units: 1
  • long_name: Flag for PCASP Concentration in size channel 1
  • var_id: PCASP_01_FLAG
  • units: 1
  • long_name: Flag for PCASP Concentration in size channel 10
  • var_id: PCASP_10_FLAG
  • units: 1
  • long_name: Flag for PCASP Concentration in size channel 11
  • var_id: PCASP_11_FLAG
  • units: 1
  • long_name: Flag for PCASP Concentration in size channel 12
  • var_id: PCASP_12_FLAG
  • units: 1
  • long_name: Flag for PCASP Concentration in size channel 13
  • var_id: PCASP_13_FLAG
  • units: 1
  • long_name: Flag for PCASP Concentration in size channel 14
  • var_id: PCASP_14_FLAG
  • units: 1
  • long_name: Flag for PCASP Concentration in size channel 2
  • var_id: PCASP_02_FLAG
  • units: 1
  • long_name: Flag for PCASP Concentration in size channel 3
  • var_id: PCASP_03_FLAG
  • units: 1
  • long_name: Flag for PCASP Concentration in size channel 4
  • var_id: PCASP_04_FLAG
  • units: 1
  • long_name: Flag for PCASP Concentration in size channel 5
  • var_id: PCASP_05_FLAG
  • units: 1
  • long_name: Flag for PCASP Concentration in size channel 6
  • var_id: PCASP_06_FLAG
  • units: 1
  • long_name: Flag for PCASP Concentration in size channel 7
  • var_id: PCASP_07_FLAG
  • units: 1
  • long_name: Flag for PCASP Concentration in size channel 8
  • var_id: PCASP_08_FLAG
  • units: 1
  • long_name: Flag for PCASP Concentration in size channel 9
  • var_id: PCASP_09_FLAG
  • units: 1
  • long_name: Flag for Particle concentration from the 2DC
  • var_id: 2DC_CONC_FLAG
  • units: 1
  • long_name: Flag for Sample flow rate through PCASP used for processing. Check header for details
  • var_id: PCASP_FL_FLAG
  • units: 1
  • long_name: Flag for droplet concentration from the PCASP
  • var_id: PCASPCON_FLAG
  • units: gram m-3
  • var_id: 2DC_IWC
  • long_name: Ice water content from 2DC
  • var_id: LONG_DATE
  • units: gram m-3
  • var_id: 2DC_LWC
  • long_name: Liquid water content from 2DC
  • units: milligram m-3
  • long_name: Mass content from PCASP
  • var_id: PCASPMAS
  • units: None
  • units: cm-3
  • long_name: PCASP Concentration in size channel 0
  • var_id: PCASP_00
  • units: cm-3
  • long_name: PCASP Concentration in size channel 1
  • var_id: PCASP_01
  • units: cm-3
  • long_name: PCASP Concentration in size channel 10
  • var_id: PCASP_10
  • units: cm-3
  • long_name: PCASP Concentration in size channel 11
  • var_id: PCASP_11
  • units: cm-3
  • long_name: PCASP Concentration in size channel 12
  • var_id: PCASP_12
  • units: cm-3
  • long_name: PCASP Concentration in size channel 13
  • var_id: PCASP_13
  • units: cm-3
  • long_name: PCASP Concentration in size channel 14
  • var_id: PCASP_14
  • units: cm-3
  • long_name: PCASP Concentration in size channel 2
  • var_id: PCASP_02
  • units: cm-3
  • long_name: PCASP Concentration in size channel 3
  • var_id: PCASP_03
  • units: cm-3
  • long_name: PCASP Concentration in size channel 4
  • var_id: PCASP_04
  • units: cm-3
  • long_name: PCASP Concentration in size channel 5
  • var_id: PCASP_05
  • units: cm-3
  • long_name: PCASP Concentration in size channel 6
  • var_id: PCASP_06
  • units: cm-3
  • long_name: PCASP Concentration in size channel 7
  • var_id: PCASP_07
  • units: cm-3
  • long_name: PCASP Concentration in size channel 8
  • var_id: PCASP_08
  • units: cm-3
  • long_name: PCASP Concentration in size channel 9
  • var_id: PCASP_09
  • units: m-3
  • long_name: Particle concentration from the 2DC
  • var_id: 2DC_CONC
  • var_id: QUALITY
  • var_id: SCANDIR
  • var_id: SECONDS
  • long_name: Sample flow rate through PCASP used for processing. Check header for details
  • var_id: PCASP_FL
  • units: cm-3 s-1
  • var_id: WAVENUM
  • var_id: ZPD_POSITION
  • units: cm-3
  • long_name: droplet concentration from the PCASP
  • var_id: PCASPCON
  • var_id: t
  • long_name: time of measurement
  • var_id: Time
  • long_name: time of measurement\0
  • standard_name: time\0

Co-ordinate Variables

Coverage
Temporal Range
Start time:
2009-05-05T04:05:26
End time:
2009-05-05T11:45:38
Geographic Extent

 
23.6410°
 
58.0619°
 
60.4292°
 
20.2142°