This website uses cookies. By continuing to use this website you are agreeing to our use of cookies. 

Dataset

 

Nitrous oxide and carbon monoxide measurements from Ho Chi Minh City, Vietnam 2018-2019

Update Frequency: Not Planned
Latest Data Update: 2026-01-20
Status: Completed
Online Status: ONLINE
Publication State: Citable
Publication Date: 2026-01-30
DOI Publication Date: 2026-02-03
Download Stats: last 12 months
Dataset Size: 2 Files | 2MB

Abstract

Continuous in situ mole fractions measurements of nitrous oxide and carbon monoxide from instruments located on the roof of an 11-storey building (∼40m) at the Vietnam National University HCMC, University of Science campus in Ho Chi Minh City, Vietnam (10.7625°N, 106.6823°E). These measurements were taken between October 2018 to March 2019 as part of the Two City study of Air Quality in Vietnam project NE/P014771/1.

Citable as:  University of East Anglia; Forster, G. (2026): Nitrous oxide and carbon monoxide measurements from Ho Chi Minh City, Vietnam 2018-2019. NERC EDS Centre for Environmental Data Analysis, 03 February 2026. doi:10.5285/c4e5b5939c3240fb823896cefadbfe75. https://dx.doi.org/10.5285/c4e5b5939c3240fb823896cefadbfe75

Abbreviation: Not defined
Keywords: nitrous oxide, carbon monoxide, vietnam

Details

Previous Info:
No news update for this record
Previously used record identifiers:
No related previous identifiers.
Access rules:
Public data: access to these data is available to both registered and non-registered users.
Use of these data is covered by the following licence(s):
http://www.nationalarchives.gov.uk/doc/open-government-licence/version/3/
When using these data you must cite them correctly using the citation given on the CEDA Data Catalogue record.
Data lineage:

This data resources were collected by the project team - the NERC funded project enitited "A Two City study of Air Quality in Vietnam" - before archival at CEDA

Data Quality:
Data are as supplied by the project team. No quality information is available
File Format:
BADC-CSV

Related Documents

No documents related to this record were found.

Process overview

This dataset was generated by instruments deployed on platforms as listed below.

Instrument/Platform pairings

Los Gatos N2O/CO analyser - UEA Deployed on: Vietnam National University HCMC
Output Description

None

  • var_id: 9
  • long_name: 5 minute average of carbon monoxide mole fraction in air
  • units: nmol mol-1
  • var_id: 6
  • units: nmol mol-1
  • long_name: 5 minute average of nitrous oxide mole fraction in air
  • var_id: 10
  • units: nmol mol-1
  • long_name: 5 minute standard deviation (1 Sigma) of carbon monoxide mole fraction in air
  • var_id: 7
  • units: nmol mol-1
  • long_name: 5 minute standard deviation (1 Sigma) of nitrous oxide mole fraction in air
  • long_name: DAY
  • units: day
  • var_id: 3
  • long_name: HOUR
  • units: hour
  • var_id: 4
  • long_name: MINUTE
  • units: minute
  • var_id: 5
  • long_name: MONTH
  • units: month
  • var_id: 2
  • long_name: YEAR
  • units: year
  • var_id: 1

Co-ordinate Variables

Coverage
Temporal Range
Start time:
2018-10-01T00:00:00
End time:
2019-03-31T00:00:00
Geographic Extent

 
10.7625°
 
106.6823°
 
106.6823°
 
10.7625°
 
Related parties
Funders (1)
Principal Investigators (1)