Dataset

 

FAAM B534 RONOCO flight, number 1: Airborne atmospheric measurements from core and non-core instrument suites on board the BAE-146 aircraft

Update Frequency: As Needed
Latest Data Update: 2015-04-30
Status: Completed
Online Status: ONLINE
Publication State: Published
Publication Date: 2014-07-14
Download Stats: last 12 months
Dataset Size: 43 Files | 2GB

Abstract

Airborne atmospheric measurements from core and non-core instrument suites data on board the FAAM BAE-146 aircraft during flight 1 for RONOCO: ROle of Nighttime chemistry in controlling the Oxidising Capacity of the AtmOsphere Consortium Project project.

Citable as:  Facility for Airborne Atmospheric Measurements; Natural Environment Research Council; Met Office (2014): FAAM B534 RONOCO flight, number 1: Airborne atmospheric measurements from core and non-core instrument suites on board the BAE-146 aircraft. NCAS British Atmospheric Data Centre, date of citation. https://catalogue.ceda.ac.uk/uuid/8e30ee54fe9741898864cf7b6ed5db26
Abbreviation: Not defined
Keywords: RONOCO, FAAM, airborne, atmospheric measurments

Details

Previous Info:
No news update for this record
Previously used record identifiers:
No related previous identifiers.
Access rules:
Restricted data: please submit an application using the REQUEST ACCESS link for access.
Use of these data is covered by the following licence: http://licences.ceda.ac.uk/image/data_access_condition/faam_core.pdf. When using these data you must cite them correctly using the citation given on the CEDA Data Catalogue record.
Data lineage:

Data were collected by instrument scientists during the flight before preparation and delivery for archiving at the NCAS British Atmospheric Data Centre.

Data Quality:
Data collected by flight participants before preparation for archival with the British Atmospheric Data Centre
File Format:
Data are netCDF and NASA-Ames formatted. Ancillary files may be plain ASCII or PDF formatted. Image files may be PNG formatted.

Process overview

This dataset was generated by instruments deployed on platforms as listed below.

Instrument/Platform pairings

FAAM/BAE (Facility for Airborne Atmospheric Measurements/British AErospace) systems: Set of FAAM core instruments Deployed on: FAAM BAe-146-301 Large Atmospheric Research Aircraft G-LUXE
FAAM: DMT Dual Column Cloud Condensation Nuclei (CCN) Deployed on: FAAM BAe-146-301 Large Atmospheric Research Aircraft G-LUXE
FAAM/BAE systems: Set of several core and/or non-core instruments Deployed on: FAAM BAe-146-301 Large Atmospheric Research Aircraft G-LUXE
Leeds: Fluorecence Assay by Gas Expansion instrument (FAGE) Deployed on: FAAM BAe-146-301 Large Atmospheric Research Aircraft G-LUXE
UEA: Formaldehyde (HCHO) instrument or Fluorometric Deployed on: FAAM BAe-146-301 Large Atmospheric Research Aircraft G-LUXE
University of Manchester/UFAM: Aerosol Mass Spectrometer (AMS) - formerly umist-ams Deployed on: FAAM BAe-146-301 Large Atmospheric Research Aircraft G-LUXE
Laquila:Noy LIF Deployed on: FAAM BAe-146-301 Large Atmospheric Research Aircraft G-LUXE
York: Dual Column Gas Chromatograph-Flame Ionization Detector (DC-GC-FID) Deployed on: FAAM BAe-146-301 Large Atmospheric Research Aircraft G-LUXE
FAAM/BAE systems: Subset of FAAM core instruments measuring cloud physics data Deployed on: FAAM BAe-146-301 Large Atmospheric Research Aircraft G-LUXE
York: PAN GC (PeroxyAcetyl Nitrate Gas Chromatograph) Deployed on: FAAM BAe-146-301 Large Atmospheric Research Aircraft G-LUXE
Laquila:No2 LIF Deployed on: FAAM BAe-146-301 Large Atmospheric Research Aircraft G-LUXE
UEA: Proton Transfer Reaction Mass Spectrometer (PTR-MS) Deployed on: FAAM BAe-146-301 Large Atmospheric Research Aircraft G-LUXE

Mobile platform operations

Mobile Platform Operation 1 FAAM BAE-146 flight B534
Output Description

None

  • units: micron
  • long_name: Calibrated channel diameter lower limits
  • var_id: PCAS2_D_L_CAL
  • units: micron
  • long_name: Calibrated channel diameter upper limits
  • var_id: PCAS2_D_U_CAL
  • long_name: Composition of the aerosol used to calibrate channel diameter lower limits
  • var_id: PCAS2_D_L_COMP
  • units:
  • long_name: Composition of the aerosol used to calibrate channel diameter upper limits
  • var_id: PCAS2_D_U_COMP
  • units:
  • units: micron
  • long_name: Error in calibrated channel diameter lower limits
  • var_id: PCAS2_D_L_ERR
  • units: micron
  • long_name: Error in calibrated channel diameter upper limits
  • var_id: PCAS2_D_U_ERR
  • long_name: Flag for droplet concentration from PCASP2 (SPP200) channels 2 to 30 included
  • var_id: PCAS2_FLAG
  • units:
  • units: micron
  • long_name: Nominal uncalibrated channel diameter lower limits as given in the instrument manual
  • var_id: PCAS2_D_L_NOM
  • units: micron
  • long_name: Nominal uncalibrated channel diameter upper limits as given in the instrument manual
  • var_id: PCAS2_D_U_NOM
  • units: ppm
  • long_name: PCASP (SPP200) Channel Number
  • var_id: PCAS2CH
  • units:
  • units: cm-3
  • long_name: PCASP2 (SPP200) conc in size channel 1
  • var_id: PCAS2_01
  • units: cm-3
  • long_name: PCASP2 (SPP200) conc in size channel 10
  • var_id: PCAS2_10
  • units: cm-3
  • long_name: PCASP2 (SPP200) conc in size channel 11
  • var_id: PCAS2_11
  • units: cm-3
  • long_name: PCASP2 (SPP200) conc in size channel 12
  • var_id: PCAS2_12
  • units: cm-3
  • long_name: PCASP2 (SPP200) conc in size channel 13
  • var_id: PCAS2_13
  • units: cm-3
  • long_name: PCASP2 (SPP200) conc in size channel 14
  • var_id: PCAS2_14
  • units: cm-3
  • long_name: PCASP2 (SPP200) conc in size channel 15
  • var_id: PCAS2_15
  • units: cm-3
  • long_name: PCASP2 (SPP200) conc in size channel 16
  • var_id: PCAS2_16
  • units: cm-3
  • long_name: PCASP2 (SPP200) conc in size channel 17
  • var_id: PCAS2_17
  • units: cm-3
  • long_name: PCASP2 (SPP200) conc in size channel 18
  • var_id: PCAS2_18
  • units: cm-3
  • long_name: PCASP2 (SPP200) conc in size channel 19
  • var_id: PCAS2_19
  • units: cm-3
  • long_name: PCASP2 (SPP200) conc in size channel 2
  • var_id: PCAS2_02
  • units: cm-3
  • long_name: PCASP2 (SPP200) conc in size channel 20
  • var_id: PCAS2_20
  • units: cm-3
  • long_name: PCASP2 (SPP200) conc in size channel 21
  • var_id: PCAS2_21
  • units: cm-3
  • long_name: PCASP2 (SPP200) conc in size channel 22
  • var_id: PCAS2_22
  • units: cm-3
  • long_name: PCASP2 (SPP200) conc in size channel 23
  • var_id: PCAS2_23
  • units: cm-3
  • long_name: PCASP2 (SPP200) conc in size channel 24
  • var_id: PCAS2_24
  • units: cm-3
  • long_name: PCASP2 (SPP200) conc in size channel 25
  • var_id: PCAS2_25
  • units: cm-3
  • long_name: PCASP2 (SPP200) conc in size channel 26
  • var_id: PCAS2_26
  • units: cm-3
  • long_name: PCASP2 (SPP200) conc in size channel 27
  • var_id: PCAS2_27
  • units: cm-3
  • long_name: PCASP2 (SPP200) conc in size channel 28
  • var_id: PCAS2_28
  • units: cm-3
  • long_name: PCASP2 (SPP200) conc in size channel 29
  • var_id: PCAS2_29
  • units: cm-3
  • long_name: PCASP2 (SPP200) conc in size channel 3
  • var_id: PCAS2_03
  • units: cm-3
  • long_name: PCASP2 (SPP200) conc in size channel 30
  • var_id: PCAS2_30
  • units: cm-3
  • long_name: PCASP2 (SPP200) conc in size channel 4
  • var_id: PCAS2_04
  • units: cm-3
  • long_name: PCASP2 (SPP200) conc in size channel 5
  • var_id: PCAS2_05
  • units: cm-3
  • long_name: PCASP2 (SPP200) conc in size channel 6
  • var_id: PCAS2_06
  • units: cm-3
  • long_name: PCASP2 (SPP200) conc in size channel 7
  • var_id: PCAS2_07
  • units: cm-3
  • long_name: PCASP2 (SPP200) conc in size channel 8
  • var_id: PCAS2_08
  • units: cm-3
  • long_name: PCASP2 (SPP200) conc in size channel 9
  • var_id: PCAS2_09
  • units: percent
  • long_name: Percentage error in PCASP2 (SPP200) conc in size channel 1
  • var_id: PCAS2_01_err
  • units: percent
  • long_name: Percentage error in PCASP2 (SPP200) conc in size channel 10
  • var_id: PCAS2_10_err
  • units: percent
  • long_name: Percentage error in PCASP2 (SPP200) conc in size channel 11
  • var_id: PCAS2_11_err
  • units: percent
  • long_name: Percentage error in PCASP2 (SPP200) conc in size channel 12
  • var_id: PCAS2_12_err
  • units: percent
  • long_name: Percentage error in PCASP2 (SPP200) conc in size channel 13
  • var_id: PCAS2_13_err
  • units: percent
  • long_name: Percentage error in PCASP2 (SPP200) conc in size channel 14
  • var_id: PCAS2_14_err
  • units: percent
  • long_name: Percentage error in PCASP2 (SPP200) conc in size channel 15
  • var_id: PCAS2_15_err
  • units: percent
  • long_name: Percentage error in PCASP2 (SPP200) conc in size channel 16
  • var_id: PCAS2_16_err
  • units: percent
  • long_name: Percentage error in PCASP2 (SPP200) conc in size channel 17
  • var_id: PCAS2_17_err
  • units: percent
  • long_name: Percentage error in PCASP2 (SPP200) conc in size channel 18
  • var_id: PCAS2_18_err
  • units: percent
  • long_name: Percentage error in PCASP2 (SPP200) conc in size channel 19
  • var_id: PCAS2_19_err
  • units: percent
  • long_name: Percentage error in PCASP2 (SPP200) conc in size channel 2
  • var_id: PCAS2_02_err
  • units: percent
  • long_name: Percentage error in PCASP2 (SPP200) conc in size channel 20
  • var_id: PCAS2_20_err
  • units: percent
  • long_name: Percentage error in PCASP2 (SPP200) conc in size channel 21
  • var_id: PCAS2_21_err
  • units: percent
  • long_name: Percentage error in PCASP2 (SPP200) conc in size channel 22
  • var_id: PCAS2_22_err
  • units: percent
  • long_name: Percentage error in PCASP2 (SPP200) conc in size channel 23
  • var_id: PCAS2_23_err
  • units: percent
  • long_name: Percentage error in PCASP2 (SPP200) conc in size channel 24
  • var_id: PCAS2_24_err
  • units: percent
  • long_name: Percentage error in PCASP2 (SPP200) conc in size channel 25
  • var_id: PCAS2_25_err
  • units: percent
  • long_name: Percentage error in PCASP2 (SPP200) conc in size channel 26
  • var_id: PCAS2_26_err
  • units: percent
  • long_name: Percentage error in PCASP2 (SPP200) conc in size channel 27
  • var_id: PCAS2_27_err
  • units: percent
  • long_name: Percentage error in PCASP2 (SPP200) conc in size channel 28
  • var_id: PCAS2_28_err
  • units: percent
  • long_name: Percentage error in PCASP2 (SPP200) conc in size channel 29
  • var_id: PCAS2_29_err
  • units: percent
  • long_name: Percentage error in PCASP2 (SPP200) conc in size channel 3
  • var_id: PCAS2_03_err
  • units: percent
  • long_name: Percentage error in PCASP2 (SPP200) conc in size channel 30
  • var_id: PCAS2_30_err
  • units: percent
  • long_name: Percentage error in PCASP2 (SPP200) conc in size channel 4
  • var_id: PCAS2_04_err
  • units: percent
  • long_name: Percentage error in PCASP2 (SPP200) conc in size channel 5
  • var_id: PCAS2_05_err
  • units: percent
  • long_name: Percentage error in PCASP2 (SPP200) conc in size channel 6
  • var_id: PCAS2_06_err
  • units: percent
  • long_name: Percentage error in PCASP2 (SPP200) conc in size channel 7
  • var_id: PCAS2_07_err
  • units: percent
  • long_name: Percentage error in PCASP2 (SPP200) conc in size channel 8
  • var_id: PCAS2_08_err
  • units: percent
  • long_name: Percentage error in PCASP2 (SPP200) conc in size channel 9
  • var_id: PCAS2_09_err
  • long_name: Refractive index of the aerosol used to calibrate channel diameter lower limits
  • var_id: PCAS2_D_L_RI
  • units:
  • long_name: Refractive index of the aerosol used to calibrate channel diameter upper limits
  • var_id: PCAS2_D_U_RI
  • units:
  • var_id: Time
  • long_name: Time UTC integer seconds past midnight
  • long_name: Time UTC seconds past midnight for PCASP2 (SPP200)
  • standard_name: Time
  • var_id: PCAS2TSPM
  • units: cm3 s-1
  • long_name: Volumetric sample flow rate through PCASP2 (SPP200)
  • var_id: PCAS2_FL
  • units: cm-3
  • long_name: droplet concentration from PCASP2 (SPP200) channels 2 to 30 included
  • var_id: PCAS2CON

Co-ordinate Variables